Repair
Cleaning the inside of the Flow Control
Cleaning
Clean the inside of the Flow Control if it is blocked or sticking, see exploded drawing
Ä further information on page 18.
1.
Unscrew the top of the dismantled Flow Control.
2.
Remove the counter-magnet and O-ring from the hole for the float.
3.
Remove the float.
4.
Clean everything with a suitable cleaning agent and tool.
5.
Check in which direction the float and counter-magnet repel each other
6.
Allow the float to slide into the hole.
7.
Flow Control 3: Use tweezers to insert the O-ring into the hole for the float.
8.
Flow Control 4 and 5: Push the O-ring from below onto the counter-magnets and push the
insert on from above.
9.
Adjust the counter-magnet so that the counter-magnet repels the float.
10.
Screw the Flow Control tightly closed.