Router Design
Circuit example:
Figure 12: Power connector pin-outs
3.7.3
Grounding the device (functional earth)
Ground the device by connecting the minus pole (GND) of the power supply
to earth. When you mount the device on a grounded DIN rail, then the DIN
rail provides the ground.The shield of a shielded twisted pair cable is
connected to the housing and the minus pole of the power supply socket.
3.7.4
Antenna Connectors
Main and diversity antennas are connected to the router using the SMA
connector on the front panel. The "ANT" connector is used to connect the
main antenna to the router. To connect the diversity antenna, use the second
"DIV" antenna connector. The "GPS" connector is intended for the GPS
antenna. The router supports an active GPS antenna.
28
3.7 Description of the Front Panel
UM Installation OWL_LTE
Release 1.0 09/2015