2.1.11

Installing the device on the DIN rail, grounding

 Mount the device on a 35 mm DIN rail in accordance with DIN EN 60175.
 Attach the upper snap-in guide of the device into the DIN rail and press
the device down against the DIN rail until it snaps into place.
Note: The shielding ground of the industrial connectable twisted pair lines is
connected to the lower panel as a conductor.
Figure 18: Assembly
Grounding
The lower panel of the device housing is grounded by means of the DIN
rail and optionally by means of the separate ground screw
2.1.12

Connecting the data lines

10/100 Mbit/s twisted pair connection
10/100 Mbit/s ports (RJ45 or M12 sockets) allow the connection of
terminal devices or independent network segments according to the IEEE
802.3 100BASE-TX / 10BASE-T standard. These ports support:
Autonegotiation
Autopolarity
Autocrossing (if autonegotiation is activated)
100 Mbit/s half-duplex mode, 100 Mbit/s full duplex mode
10 Mbit/s half-duplex mode, 10 Mbit/s full duplex mode
Delivery condition: Autonegotiation activated except for the HIPER-Ring
port: 100 Mbit/s, full duplex
The socket housing is electrically connected to the bottom panel.
46
(see fig.
2).
MS20/MS30 MS20/MS30
Release 10 07/2012

Advertisement