Before You
Configure ATM
Checking
ATM Link Status
Before you configure ATM, follow these steps:
Check the ATM link status.
Verify that address registration is operational.
Verify that signalling is operational.
To check the link status, follow these steps:
1 From the top level of the Administration Console, enter:
atm ume display
You are prompted for the number(s) of the UME that you want to display.
2 Enter the number(s) of the UME(s) or all.
Sample ATM UME display:
reqState
connected
vpi
0
connCount
2
dropRxPdus
0
The state field should show connected. If the state field shows
disconnected, there is a problem with the link. If this happens, check
the cabling to ensure that the CoreBuilder 2500 system is correctly
connected to the ATM switch.

Before You Configure ATM

state
connected
reqVci
16
discCount
2
txPdus
209
37
reqVpi
0
vci
16
rxPdus
232