Service And Display Messages; Warning Messages - Martin MAC Allure Wash PC User Manual

Table of Contents

Advertisement

Service and display messages

The MAC Allure Wash PC gives service and maintenance information by displaying a large 3- or 4-character
short code and a smaller full-text message in the fixture's display. The short code is visible at a distance,
allowing easier reading with the fixture still in the rig, for example, while the full-text message gives more
detailed information.

Warning messages

Warning messages indicate that either:
• problems might appear in the future if no action is taken, or
• the user needs to pay special attention to a function or procedure when working with the fixture.
The MAC Allure Wash PC communicates warnings as follows:
• Warning codes are shown continuously in the display and disappear when the user reacts to the warning.
• If more than one warning is detected, all warnings are displayed in sequence.
• If the display is inactive, the fixture's status LED (see Figure 2 on page 8) flashes orange to indicate that
there is a warning. Activating the display will show the warning.
The possible warning messages are listed in Table 5 below
Short code
BANK
DCTW
LDTW
PFTW
PTTW
SERV
SL W
UITW
ZFTW
*High temperature warnings are canceled as soon as temperature returns to normal. If temperature reaches
cutoff level, the warning is replaced by a cutoff error message.
Long message and explanation
BANK NO ACCESS
Error unpacking firmware bank during/after software upload. Fixture will continue to operate on
existing firmware. Warning message is cleared by a successful software upload or at the next
power off/on cycle.
DC TEMP HIGH
DC PCB sensor detects abnormally high operating temperature.*
LED DRV TMP HIGH
LED driver temperature sensor detects abnormally high operating temperature.*
PFC TEMP HIGH
PFC unit temperature sensor detects abnormally high operating temperature.*
PT TEMP HIGH
Pan/tilt PCB sensor detects abnormally high operating temperature.*
SERVICE MODE
Fixture in service mode.
SAFETY LOOP
A safety loop error occurred but is no longer active. Warning message is cleared at the next
power off/on cycle.
UI TEMP HIGH
User interface (LCD display and control panel) PCB sensor detects abnormally high operating
temperature.*
ZF TEMP HIGH
Zoom PCB sensor detects abnormally high operating temperature.*
Table 5: Warning messages