Power Head Disassembly/Replacement - Pentair FLECK 5800 XTR Installer Manual

Hide thumbs Also See for FLECK 5800 XTR:
Table of Contents

Advertisement

Installer Manual Fleck 5800 - XTR - Maintenance

9.2.4. Power head disassembly/replacement

No.
A
Remove the controller, see 9.2.2. Replacing the controller, page 96.
B
Using a 6 mm wrench or flat screwdriver, unscrew (2).
C
Using a 8 mm wrench or flat screwdriver, unscrew (1).
D
Separate the power head (3) from the valve body (4).
E
Change the power head (3).
Reverse above procedure steps to rebuild. Mind the core marker and align the small holes
F
of the gears for easy reassembly.
Caution
When assembling the gearing system (3) on the valve body (4), make sure to put the
brighter part of the piston axe (5) on the left as shown beside.
Tip
These operations need to be performed before any cleaning or maintenance procedure.
98 / 122
Operation
Ref. MKT-IM-006 / B - 16.01.2018