FILTER CARTRIDGE REPLACEMENT

A) Place a pan under the unit to catch any spilled water. Turn off water
supply to !lter. Depress red pressure-relief button on top of !lter. Use
housing wrench to unscrew bottom of housing. Turn slowly to the left
and support the housing and piping as you loosen the housing.
NOTE: If turning off water supply to the !lter will also turn off water
supply to the rest of the home, be sure to !ll a bucket of water !rst to
allow you to clean the housing after it has been removed.
B) Pour out the water from the housing and remove and discard the old
cartridge. Locate and remove large O-ring, wipe clean of lubricant
and set aside. Rinse out bottom of housing and !ll about 1/3 full with
water. Add about 2 tablespoons of bleach and scrub cap and bottom
of housing with nonabrasive sponge or cloth. Rinse thoroughly. Check
O-ring for damage. If cut, scratched, or stretched, replace it with a
new one. If the O-ring is in good condition, lubricate it with clean
silicone grease, insert it back into groove and smooth into place with
!nger. Insert new cartridge over standpipe in bottom of housing.
C) Screw bottom of housing onto the cap and hand-tighten.
DO NOT OVER-TIGHTEN. Turn on water supply slowly to allow !lter
to !ll with water. Depress red pressure-relief button to release trapped
air. Check for leaks before leaving installation.
NOTE: After installation, !ush the cartridge for 10 minutes, wait one
hour, then !ush again for 10 minutes before using the water.
NOTE: Use only genuine OMNIFILTER replacement cartridges for best
results. Failure to use OMNIFILTER replacement cartridges will void
your warranty.

TROUBLESHOOTING

Leaks between cap and bottom of housing:
1. Turn off water supply and depress pressure-relief button.
2. Clean and lubricate O-ring with silicone grease. Also, clean the groove
where the O-ring seats with a clean cloth. Replace O-ring back in
groove above threads. Screw bottom of housing back on cap securely
by hand. DO NOT OVER-TIGHTEN.
3. Turn on water supply. If leaks persist, or if there are other leaks on the
system, turn off water supply. Call OMNIFILTER Customer Service at
800.279.9404.
Leaks on inlet/outlet connections:
1. Turn off water supply. For brass !ttings, tighten nut 1/2-turn
with wrench.
2. Turn on water supply. If leaks persist, or if there are other leaks on
system, turn off water supply. Call OMNIFILTER Customer Service at
800.279.9404.

MAINTENANCE

Contact your local area retailer for replacement cartridge pricing.
The BF7 is covered by a limited 5 year warranty. See warranty
for details.