6.4.5. Relay output screen

From the master settings screen press the relay button to display the relay output screen.
auxiliary 1/auxiliary 2: Contains settings for programming up to two auxiliary relay outputs. There
are four types of signals that can be programmed:
alarm based: The relay will turn on when the specified alarm condition (or any alarm condition) is met.
The relay will turn off when the alarm is cleared.
cycle based: The relay will turn on when the valve moves to the specified regeneration cycle steps. To
program, select each cycle step button for which the relay should turn on.
time based: The relay will turn on and off at up to two specified start and end times.
volume based: The relay will turn on when the valve has treated a specified volume of water. Duration
can be set for up to two hours.
Note
This option will not be available if regeneration type is set to timeclock.
Press
to save and pass to the relay settings or press
without saving.
Ref. MKT-IM-006 / B - 16.01.2018
Installer Manual Fleck 5800 - XTR - Programming
Relay Output
auxiliary 1
auxiliary 2
alarm
based
off
to return to the master settings screen