Installer Manual Fleck 5800 - XTR - System sizing
4.

System sizing

4.1.

Recommendations

4.1.1. Injector/DLFC/BLFC-Valve configuration

Diameter
Valve
type
[in]
4
6
7
8
9
5800/
1650
10
12
13
14
16
Note
In upflow configuration, the injector cap is fitted with a pressure regulator set to 1.4 or 2 bar.
4.2.

Sizing a softener (single unit)

4.2.1. Parameters to be considered

Whenever installing a softener, it is preferable to have full water analysis to ensure the inlet water
content will not affect the resin bed.
Note
Please consult your resin manufacturer specifications to ensure that no additional
pretreatment prior to softening is required.
26 / 122
Resin
volume
L
DF
Color
4
5 - 7
0
Red
8 - 14
9 - 21
22 - 28
1
White
29 - 42
43 - 56
2
Blue
57 - 70
71- 85
3
Yellow
86 - 113
Injector
UF
Color
0000
Black
000
Brown
00
Violet
0
Red
1
White
2
Blue
Ref. MKT-IM-006 / B - 16.01.2018
DLFC
BLFC
[gpm]
DF [gpm] UF [gpm]
0.8
0.125
1.2
1.5
2
0.25
2.4
3.5
4
0.50
5
7
0.125
0.25
0.50