92 • 5. Balancing Features and Options
Measure the weight plane diameter manually, using caliper.
NOTE:
This may need to be done before the wheel is mounted on
the GSP9700.
Add the measurement from the left weight plane to the desired right weight plane to
the distance to the inner rim lip and enter this new dimension manually.
Enter the weight plane distance (mm) and diameter (in) manually.
Close safety hood.
Press the green "START" button if "Hood Autostart" is disabled.
After wheel comes to a complete stop, raise safety hood.
Place left plane weight (if in DYNAMIC mode) per the balance procedure being
performed. Refer to "Balancing Procedures," page 35.
Press the green "START" button with the safety hood in the RAISED position and the
GSP9700 will servo to the location for the right adhesive weight plane (dynamic) or
the static adhesive weight plane (static), aligned with the first spoke.
With the servo enabled, attach the adhesive weight behind the first spoke using the
weight amount shown on the CRT.
Press the green "START" button with the safety hood in the RAISED position and the
GSP9700 will servo to the location for the second spoke.
Attach the appropriate weight as displayed on the console.
Verify balance condition by spinning again with the load roller disabled. Refer to
"Load Roller Operation," page 60.
All weight plane displays should show "zero."
®
SPLIT SPOKE
balancing procedure is complete.
GSP9700 Series Road Force Measurement System Operation