Canon D1300 Series Service Manual page 95

Table of Contents

Advertisement

4
Disassembly/Assembly > Controller System > Removing the Main Controller Board
2) Remove the Main Controller Board [1].
• 7 Screws [2]
[2]
Actions after Replacement
1) Error code "E248-0001" lights up when turning ON the power.
2) Execute COPIER > FUNCTION > CLEAR > R-CON.
3) Enter all items written on the service label.
4) Set the location group and paper size group.
• COPIER > OPTION > BODY > LOCALE (setting the location group)
[Setting value]
1: Japan, 2: North America, 3: Korea, 4: China, 5: Taiwan, 6: Europe, 7: Asia, 8:
Oceania
• COPIER > OPTION > BODY > SIZE-LC (setting the paper size group)
[Setting value]
1: AB configuration, 2: Inch configuration, 3: A configuration, 4: AB/Inch configuration
5) Clearing the Settings/Registration data
Execute COPIER > FUNCTION > CLEAR > ALL.
When executing this item, the following data is cleared according to the values of LOCALE
and SIZE-LC set in step 4.
• Settings/Registration data (the initial value according to the location is set.)
• Service mode data (the initial value according to the location is set.)
• Job ID
• Each log data
• Date data
Note that the following data is not cleared.
• Service counter
• Adjustment value of Reader/DADF
4
Disassembly/Assembly > Controller System > Removing the Main Controller Board
[2]
x7
[1]
[2]
F-4-104
6) Execute COPIER > FUNCTION > VIFFNC > STOR-DCN (the setting value of DC Controller
is backed up.)
7) Turn OFF and then ON the power.
8) Operate according to the instruction on the screen since the initial installation mode is
activated. (Setting the date/time, executing the auto gradation adjustment)
9) Enter the serial number (8-digit alphanumeric) in Settings/Registration > System Settings >
Device Information > Location.
10) After selecting COPIER > OPTION > SERIAL > SN-MAIN, press OK key to write the
serial number entered in step 4 in the Main Controller PCB. After writing, the serial number
entered in "Location" in step 9 is deleted.
11) Turn OFF and then ON the main power.
12) Execute COPIER > FUNCTION > MISC-P > SPEC to output the spec report to check the
serial number (Body.No.).
13) Enter the data backed up earlier in Settings/Registration > System Settings > Device
Information > Location.
14) Import the service mode data backed up before replacement.
Insert the USB memory storage device to the slot of the machine, and execute COPIER >
FUNCTION > SYSTEM > IMPORT.
15) Import user data using remote UI.
4-43
4-43

Advertisement

Table of Contents
loading

Table of Contents