Wiring and Grounding Guidelines for PanelView Plus Terminals
PanelView Plus
Isolated DC Terminals
The 700 to 1500 terminals with an isolated DC power input use the following:
• Isolated DC logic module
• Earth/ground connection
Terminals with an isolated DC logic module do not require a separate power
supply to power multiple devices.
Isolated DC Logic Modules
All PanelView Plus 6 terminals (700 to 1500 models) that operate on DC power
use an isolated DC logic module. Some PanelView Plus 700 to 1500 terminals
running FactoryTalk View ME software, version 5.1 or earlier, support logic
modules with an isolated DC power input.
Table 5 - Isolated DC Logic Modules
Cat. No.
Logic Modules with Isolated DC Power Input
PanelView Plus 6 Terminals (700 to 1500)
2711P-RP8D
Logic module with 512 MB nonvolatile memory and RAM
2711P-RP8DK
Conformal-coated logic module with 512 MB nonvolatile memory and RAM
2711P-RP9D
Logic module with 512 MB nonvolatile memory and RAM
2711P-RP9DK
Conformal-coated logic module with 512 MB nonvolatile memory and RAM
PanelView Plus 700 to 1500 Terminals
2711P-RP1D
Marine-certified logic module with 64 MB nonvolatile memory and RAM
2711P-RP2D
Marine-certified logic module with 128 MB nonvolatile memory and RAM
2711P-RP6D
Marine-certified, CE logic module with 128 MB nonvolatile memory and RAM
2711P-RP2DK
Conformal-coated logic module with 128 MB nonvolatile memory and RAM
2711P-RP6DK
CE conformal-coated logic module with 128 MB nonvolatile memory and RAM
2711P-RP3D
Marine-certified logic module with 256 MB nonvolatile memory and RAM
2711P-RP7D
Marine-certified CE logic module with 256 MB nonvolatile memory and RAM
(1) These logic modules support FactoryTalk View ME software, version 5.1 or earlier.
Refer to
IMPORTANT
communication port isolation.
External Power Supply for Isolated DC Terminals
Use a SELV or PELV, 24V DC power supply, such as catalog number
2711P-RSACDIN, to power a PanelView Plus 700 to 1500 terminal with an
isolated DC logic module
The isolated DC terminals may be powered by the same power source as other
equipment, a DC power bus.
ATTENTION: Use a SELV or PELV supply as required by local wiring codes
for your installation. The SELV and PELV power sources provide protection
so that under normal and single fault conditions, the voltage between
conductors and earth/ground does not exceed a safe value.