Electronic pellet burner controller – NPBC-V3C-1/ NPBC-V4C-1
Hydraulic scheme of the outside heating and hot water installation, controlled by NPBC-V3
M
ECHANISMS AND SENSORS CONTROLLED BY
Electric feed screw motor to transfer the fuel from the bunker to the burner (power up to
180W)
Electric internal auger motor to forward the fuel to the burning chamber (power up to 180W)
Main blower with smooth speed control to regulate the air flow (power up to 180W)
Additional cleaning fan (power up to 900W)
Exhaust gases fan with smooth speed control (power up to 180W)
Heating element to fire the pellets (power up to 800W)
Hot water heater circulation pump (power up to 180W)
Central heating installation circulation pump (power up to 180W)
(Optional) Analog output for frequency inverter to power up a powerful air fan
Photo sensor to detect the burning fire
Temperature sensor or thermostat to control the back burning
Temperature sensor to control the temperature of the water in the boiler
Temperature sensor for the hot water heater
High temperature pt100 sensor to measure the temperature of the flue gases. This temperature
sensor does not detect the burning fire, but only provides information
A potential free contact of a room thermostat for better control of the burning process
according to the room temperature.
USB interface for connection with a computer