Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K Electronic Pellet Burner Controller FOR DRY PELLET STOVE NPBC-V3C-K NPBC-V4C-K NPBC-V4E-K 57/28 OFTWARE VERSION User Manual / ver3.8 Page 3 of 33...
Page 2
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K HANGES IN MANUAL FOR THE WORK AND THE SOFTWARE OF THE CONTROLLER User Manual Changes Pages version Software version 27/14. • New way of dismissing the alarms for registered problems. Most of •...
Page 3
The pulsing control of the auger motor from the pellet tank allows the precise dosing of the amount of pellets that goes to the burner. NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K can control an optional internal auger motor that forwards the pellets inside the burner.
Page 4
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K MECHANISMS AND SENSORS CONTROLLED BY NPBC-V3C-K NPBC-V4C-K NPBC-V4E-K • Electric feed screw motor to transfer the fuel from the bunker to the burner (power up to 180W). • Electric internal auger motor to forward the fuel to the burning chamber (power up to 180W) .
Page 5
Factory Settings → Burning Setup → Fuel X → Unfolding Fire. The next phase is the burning control. NPBC-V3C-K or NPBC-V4C-K has settings for 4 different power levels. Three of them are used for the burner's normal work. The 4th power level maintains the burning fire to avoid unnecessary cycles of extinguishing, cleaning and ignition when the water in the boiler has reached the set temperature.
Page 6
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K heating installation for longer period of time, the burner turns off. The portion of pellets for each power level is a function of the auger motor's capacity and activate time and the cycle between two of its turnings on.
Page 7
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K EXPLOITATION INSTRUCTIONS NPBC-V3C-K / NPBC-V4C-K Control module has 6 buttons to navigate through the menus: Menu / On/Off Navigation buttons with different functions depending on the current menu Micro USB...
Page 8
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K Animated moving pictures indicate when any of the auger motors or the main fan are currently active. A flame in the boiler is a real time indication for the burning fire, detected by the photo sensor.
Page 9
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K How to turn the pellet stove on/off: Press the On/Off button to enter the switch mode menu: Currently selected row ▲ ▼ Press the up or down navigation buttons ( ) to select a row and confirm your choice by pressing the On/Off button.
Page 10
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K mode and Intermediate cleaning) are executed according to the set parameters for the currently selected fuel type. While in Timers mode, the burner works only during the time intervals when its work is allowed.
Page 11
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K Additional information and statistics While on main screen, press the right navigation button (►) to access the additional information and statistics screens. Statistics charts about the pellet consumption The first group of information screens is about the pellet consumption. Press the up or down ▲...
Page 12
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K To reset the total pellet consumption press and hold the Menu button for more than 2 seconds. To go back to Pellet consumption charts, press the left navigation button (◄).
Page 13
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K Diagnostics While on any of the Information screen pages, press the right navigation button (►) to access the Diagnostics screen. To go back to the previous screen press the left navigation button (◄). This is a listwith short description, date and time of every registered event or error message.
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K No Exec module No connection with the Executive module Power On Date and time when the power supply to the controller was turned on Power Off Date and time when the power supply to the...
Page 15
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K sub-menu with list choice again. While looking at any screen with parameter settings, press the left navigation button to go back to the previous screen with list choice. Screen title...
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K User settings While on main screen, press the Menu button once to access the User Settings. Press the up or down navigation buttons to move the red line that indicates the selected row. Press the right navigation...
Page 17
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K Timers – Set and activate time intervals when the burner's work is allowed. If even one timer is activated, the burner will work only during this interval. Moreover, the rest of the required conditions must also be presented, such as: the work mode must be anything but “Standby”, the...
Page 18
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K Select Fuel – Select the preset fuel profile settings corresponding to the currently used fuel. All parameters for each profile must be set from Burning Setup menu in Factory Settings: Display –...
Page 19
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K Manual Feeding – Manual control of the fuel auger motor and the circulation pumps. This function is useful to fill up the auger motor when it's empty, to measure its capacity of pellet feeding for calibration purposes, to test the pumps or to fill up the installations with fluid.
Page 20
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K 360 seconds (6 minutes) New WiFi network – If NRC-6 is equipped with a WiFi module for Internet connection, this menu helps with its initial setting or when changing the WiFi network.
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K Factory settings. These menus concern the burner's general control, burning process and safe usage. Because of the importance of these parameters, the access to the Factory Settings can be restricted with an access code.
Page 22
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K Common factory settings for all types of fuel: Equipment – Enable/disable the additional mechanisms and sensors of the burner's configuration and set the polarity of the room thermostat's and the OD input's contacts:...
Page 23
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K Flame Detection – Set the temperature difference for successful ignition and extinction and the maximum time for the extinguishing procedure The ignition is successful, if the current temperature of the exhaust gases is 20°C higher than it was in...
Page 24
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K RT Control – Set the time for decreasing the power level when the burner is on CH priority mode. When the room thermostat activates due to reaching the set temperature, the burner continues working on the current power level for as long as it is set in the menu RT Control.
Page 25
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K Change code – Enable/Disable the access code for the Factory Settings. The code could be any up to 6-digit combination. It is not necessary to use all of the digits. Changing only one of them is a valid code.
Page 26
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K Fuel dependent settings Press and hold the Menu button to enter the Factory Settings. Select the row Burning Setup and press the right navigation button (►). Select the fuel type and press the right navigation button again.
Page 27
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K If the controller detects a successful ignition the procedure will be terminated and the burner proceeds to unfolding the fire. Unfolding – Right after the ignition the burner doesn't switch immediately to full power, because this might extinguish the unsteady fire.
Page 28
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K depends on the system's inertia and the set temperature differences in the menu Factory Settings → Power Modulation. The shortest switch time interval could be the cycle between two feedings, which usually is 20-30 seconds.
Page 29
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K Additional information about the controller After the power supply to the controller is on, a yellow text with Control module's version appears on the screen for 2 seconds. There are two options for this text: NRC-6 MV – a control module for pellet burner or NRC-6 SV –...
Page 30
Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K О NPBC-V3C-K NPBC-V4C-K БХВАТ НА НАСТРОЙВАНИТЕ ПАРАМЕТРИ В Menu Parameter Unit Default Display Brightness level Fan on °C Convection fan Hysteresis °C Operation Burner feeder Extra sec seconds General settings Max temperature °C...