Manual Feeding; Where Ac Is The Auger Motor's Capacity - Naturela NPBC-V3C-1 User Manual

Electronic pellet burner controller
Hide thumbs Also See for NPBC-V3C-1:
Table of Contents

Advertisement

Electronic pellet burner controller – NPBC-V3C-1/ NPBC-V4C-1
Manual Feeding – Manual control of the fuel auger motor and the circulation pumps. This function is
useful to fill up the auger motor when it's empty, to measure its capacity of pellet feeding for
calibration purposes, to test the pumps or to fill up the installations with fluid. The up and down
navigation buttons (
navigation buttons (◄ ►) switch between the parameters.
The maximum time for manual control is 370 seconds (6 minutes and 10 seconds). After that the
controller turns off the outputs and switches to the previous screen.
Follow these steps to calibrate the fuel auger motor:
1. Detach the auger from the burner, but not from the fuel bunker.
2. Turn on the manual feeding to fill up the whole auger with pellets. If 370 seconds are not enough,
repeat this step several times. When the auger is full stop the manual feeding.
3. Place a bucket or another tank at the end of the auger motor to collect the pellets.
4. Start the manual feeding again and leave the auger working for any exact period (see a list with the
recommended periods for this setting in table 3)
5. Remove the bucket and measure the weight of the collected pellets in kilograms.
6. Calculate the auger motor's capacity with the following formula:

where Ac is the auger motor's capacity

F is the weight of the collected fuel in kilograms
C is the constant from table 3 corresponding to the active time of the auger motor during the manual
feeding, measured by the timer in the menu Manual Feeding
Table 3
Active time of the auger motor, measured by the timer in the menu Manual Feeding
120 seconds (2 minutes)
150 seconds
180 seconds (3 minutes)
240 seconds (4 minutes)
300 seconds (5 minutes)
360 seconds (6 minutes)
User Manual / ver 3.8
▲ ▼
) check/uncheck the box to turn on/off the output and left and right
http://www.naturela-bg.com/en/
Ac = F*C,
Timer for the auger motor's
active time
Constant C
30
24
20
15
12
10