ELECTRONIC CONTROLLER
FOR PELLET STOVE WITH WATER JACKET
NPBC-V6T-2
58/29
SOFTWARE VERSION
User Manual / ver. 1.2
http://www.naturela-bg.com/en/
page 1 of 41

Advertisement

loading

Summary of Contents for Naturela NPBC-V6T-2

  • Page 1 Electronic pellet burner controller - NPBC-V6T-2 ELECTRONIC CONTROLLER FOR PELLET STOVE WITH WATER JACKET NPBC-V6T-2 58/29 SOFTWARE VERSION User Manual / ver. 1.2 http://www.naturela-bg.com/en/ page 1 of 41...
  • Page 2 Electronic pellet burner controller - NPBC-V6T-2 HANGES IN MANUAL FOR THE WORK AND THE SOFTWARE OF THE CONTROLLER User manual Changes Page version Changed and updated version to 58/29 • Added option for changing the set temperature with gestures and •...
  • Page 3 Electronic pellet burner controller - NPBC-V6T-2 NTRODUCTION The controller NPBC-V6T-1 is using the new control module with 3.5'' IPS display with capacitive Touch sensor -NRC-8. The standart '' Executive '' module for the controller is NBPC- V4E-1. It is also possible to work with older version of the executive modules – NPBC-V4C.
  • Page 4 Electronic pellet burner controller - NPBC-V6T-2 Controllers NPBC-V6T-2 are designed to control burners , using increasing or decreasing the temperature of the exhaust gases for detecting ignited or extinguished fire. The measuring is with the high temperature sensor pt 100, mounted in the beginning of the chimney. The dosing of the pellets fed to the fire is done by pulse switching on the auger from the pellet tank.
  • Page 5 Electronic pellet burner controller - NPBC-V6T-2 Mechanisms and sensors controlled by NPBC-V6T-1 • Electric feed screw motor to transfer the fuel from the bunker to the burner (power up to 180 W) • Electric internal auger motor to forward the fuel into the burning chamber (power up to 180W) •...
  • Page 6 Electronic pellet burner controller - NPBC-V6T-2 User Manual / ver. 1.2 http://www.naturela-bg.com/en/ page 6 of 41...
  • Page 7 Electronic pellet burner controller - NPBC-V6T-2 NPBC-V 6T -2 NPUTS AND OUTPUTS OF Outputs Inputs Main fan Room thermostat. To this input could be connected a normally opened or normally closed contact, with no additional voltage. Fan for the flue gases...
  • Page 8 Electronic pellet burner controller - NPBC-V6T-2 AY OF OPERATION A burner controlled by NPBC-V6T-2 can work in continuous automatic mode or in timer mode. While in timer mode, the burner works only during the intervals of the day and the days of the week set from the user by heating to the temperature entered according to the timer.
  • Page 9 Electronic pellet burner controller - NPBC-V6T-2 The next step is burning control with power modulation. The controller supports settings for 4 different power levels. Three of them are used for normal burners' work and for the heating of the boiler. The 4th power level maintains the burning fire to avoid unnecessary cycles of extinguishing, cleaning and ignition when the water in the boiler has reached the set temperature.
  • Page 10 Electronic pellet burner controller - NPBC-V6T-2 The controller uses another method of intermediate cleaning, in which the fire is not extinguished, but only increases the power of the fan or activates the FC output to activate some cleaning mechanism. The necessary settings for this cleaning method are set from the menu "Service settings"...
  • Page 11 Electronic pellet burner controller - NPBC-V6T-2 XPLOTATION INSTRUCTION The controller NPBC-V6T-2 is controlled from ”Control module” NRC-8. It has 3.5 '' IPS display with capacitive touch sensor. It has virtual buttons or active places for control as well as by sliding your finger in a certain direction (gesture).
  • Page 12 Electronic pellet burner controller - NPBC-V6T-2 The operation of the two augers, the fan and the circulation pumps is visualized with the animated image in the middle of the main screen. When the photo sensor detect fire, a flame will appear in the boiler.
  • Page 13 Electronic pellet burner controller - NPBC-V6T-2 Blue staus bar icons: Internet connection Active room thermostat (Set temperature is reached) Аdditional control module with room thermostat function NRC-8-SV On. Active FC ( output FC) Active additional output AUX Active DHW Pump...
  • Page 14 Electronic pellet burner controller - NPBC-V6T-2 Work with Touch display The NRC-8 control module has a touch sensor positioned over the entire screen area. The control of the controller is made through the settings menus, and depending on the type of screen and the type of parameter set, appears a virtual numeric or alphanumeric keypad, delete button, navigation buttons and others.
  • Page 15 Electronic pellet burner controller - NPBC-V6T-2 Exit to the mainscreen button Indicator for Marked row. more rows. If press „>“, To see them you will select the you have to move function on this row the screen down Return button...
  • Page 16 Electronic pellet burner controller - NPBC-V6T-2 Switch is On Switch to marked CheckBox Switch is Off Main screen buttons Direction to slide on Select mode button the finger on the first information screen Button to change the set temperature Available area for...
  • Page 17 Electronic pellet burner controller - NPBC-V6T-2 The information screen can be changed with the navigation buttons and by gestures when sliding the finger on the screen in the desired direction. When switching through the main informational screens the surface should be pressed and slided horizontally or vertically more than half the screen.
  • Page 18 Electronic pellet burner controller - NPBC-V6T-2 Turn On/Off the burner: Pressing On / Off button in the middle of the screen displays a menu for mode select: Mode refusal and back to Selected row main screen Confirm selection of the marked mode Changing of the mode can be made with virtual buttons “▲”...
  • Page 19 Electronic pellet burner controller - NPBC-V6T-2 When the burner is turn On, at first it will be displayed the field “Number of fuel”. If all the conditions for ignition of the burner are fulfilled, as for example - the temperature of the boiler is...
  • Page 20 Electronic pellet burner controller - NPBC-V6T-2 Statistics of pellet consumption by hours. The first information is “Pellet consumption” screen, which contains charts with pellet consumption for the last 4 days. First is the information for the current day that is displayed, and with the buttons “▲”...
  • Page 21 Electronic pellet burner controller - NPBC-V6T-2 Information about the Wi-Fi modem and the Internet connection From the screen “Information” to go to screen “Wi-Fi” connection you must press the button “▼”. You can do it and by gesture- sliding on the screen to the top of the display.
  • Page 22 Electronic pellet burner controller - NPBC-V6T-2 Diagnostic Pressing the "►" button when the controller is in one of the text information screens, goes to the "Diagnostics" screen, which is a list of information about all the registered errors and the exact time and date of its occurrence.
  • Page 23 Electronic pellet burner controller - NPBC-V6T-2 Flue gasses alarm Button The exhaust temperature is extremely high and the burner has stopped Menu settings Date and time of the last access to the Settings menu No Exec module No connection with the Executive module...
  • Page 24: Parameter Settings

    Electronic pellet burner controller - NPBC-V6T-2 Parameter settings. In the NPBC-V6T controller all parameters except the set temperature are changed from the main menu, which is display by pressing a button from the main screen. The user settings, which are used from the end consumer of the heating system are accessible directly from this menu.
  • Page 25 Electronic pellet burner controller - NPBC-V6T-2 Timers – Setting and activating time intervals in which the operation of the burner to be allowed and the temperature to which the boiler to heat. If at least one of the three timers is active, the burner will only operate in the intervals indicated by the active timers! Outside these intervals, the burner will be extinguished.
  • Page 26 Electronic pellet burner controller - NPBC-V6T-2 Display - „Brightness“ field changes the brightness of the display. The "Display date" field indicates whether the date should be displayed in the bottom bar of the main screen when there is other information that is displayed - burner operating phase or error messages. When date display loading is turned off, the date is still displayed, when there is no other display information in the bottom row of the main screen.
  • Page 27 Electronic pellet burner controller - NPBC-V6T-2 Field "Pump operation" can have the following options: Heating – Working only the circulation pump for central the heating installation. The • circulation pump of the heating system is turned on when the temperature of the water in the boiler reaches the temperature set to the "Pump on"...
  • Page 28 Electronic pellet burner controller - NPBC-V6T-2 Parallel pumps- both the central heating and the domestic hot water installations work. • The burner and the pumps work as in DHW priority. The only difference is that the central heating circulation pump is allowed to work together with the DHW pump.
  • Page 29 Electronic pellet burner controller - NPBC-V6T-2 By pressing the button ,the module will switch to Access point mode by displaying the screen below, the name of the new network, the password and the encryption method that must be entered. Name's of a new...
  • Page 30: Service Settings

    Electronic pellet burner controller - NPBC-V6T-2 Service settings These menus concern the burner's general control, burning process and safe usage. Because of the importance of these parameters, the access to the Service Settings can be restricted with an access code. This option is disabled by default. To enable it go to the menu Service Settings » Change Code.
  • Page 31 Electronic pellet burner controller - NPBC-V6T-2 Service Settings for all types of fuel Equipment- Enable/disable the additional mechanisms and sensors of the burner's configuration and set the polarity of the room thermostat's and the OD input's contacts. The OD input function can be ''External stop '' , and when it is active, the burner will be forcibly extinguished and will ignite only after its release.
  • Page 32 Electronic pellet burner controller - NPBC-V6T-2 Flame detection - It is set how much the temperature of the exhaust gases shoud be increase or decrease for detecting fire or extinguished fire and what is the maximum time after stopping the pellet feeding after which fire should be considered for extinguished.
  • Page 33 Electronic pellet burner controller - NPBC-V6T-2 If the room thermostat is active, the burner will work on P2 for 60 seconds After another 60 seconds from P2 to P1 etc Additional cleaning – Here are the options for the use of an additional fan or other cleaning mechanism connected to the FC output is set during the cleaning cycles.
  • Page 34 Electronic pellet burner controller - NPBC-V6T-2 Safety Setup – If there is an installed high temperature sensor for the exhaust gases, it will be used to display an alarm, for decreasing the power of the burner or extinguishing the burner when the temperature of the exhaust gases gets higher then the set initially in this menu temperatures.
  • Page 35 Electronic pellet burner controller - NPBC-V6T-2 At other than 0 FM output will be powered Power switch for output SF Inputs Status - This is a service screen that displays the status of all controller inputs in real time. User Manual / ver. 1.2 http://www.naturela-bg.com/en/...
  • Page 36 Electronic pellet burner controller - NPBC-V6T-2 Fuel dependent settings The access of this setting is through menu ''Service settings » Burning setup» where you must choose ''Fuel 1''»''Fuel 2''» ''Fuel 3'' or ''Fuel 4''. Cleaning – From this menu is the setting for the duration of the cleaning cycles, with the time for work of the main fan.
  • Page 37 Electronic pellet burner controller - NPBC-V6T-2 Unfolding- This control menu is for the process of smoothly unfolding the fire after its ignition. The upper field sets the fans' speed, main fan and exhaust fan and the duration of burning of the first fuel dose.
  • Page 38 Electronic pellet burner controller - NPBC-V6T-2 It is important when setting the power Suspend, parameters not to allow increasing of the cycle between two feeding of the pellets and then the pellets in the burning chamber to burn out, and...
  • Page 39 Electronic pellet burner controller - NPBC-V6T-2 Additional information about the controller After the power supply to the controller is on, a yellow text with Control module's version appears on the screen for 2 seconds. There are two options for this text: NRC-8MV – a control module for the pellet burner or NRC-8 SV –...
  • Page 40 Electronic pellet burner controller - NPBC-V6T-2 SETUP PARAMETERS RANGE FOR NPBC-V6T-2 Menu Parameter unit Default Display Brightness level Pump On °C Ch pump Hysteresis °C Pump settings WH set temp °C DHW pump Hysteresis °C Operation Burner feeder Extr. Sec.
  • Page 41 Electronic pellet burner controller - NPBC-V6T-2 speed Duration seconds speed Unfolding fire Exhaust fan speed Р1 seconds Р2 seconds Feed seconds 25.0 Cycle seconds Setup Р1 speed Exhaust fan speed Feed seconds 25.0 Cycle seconds Setup Р2 speed Exhaust fan...