Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1
Electronic Pellet Burner Controller
NPBC-V3M-1
S
3.3a/3.2
OFTWARE VERSION
User Manual / version 2.6
http://www.naturela-bg.com/en/
page 1 of 28

Advertisement

loading

Summary of Contents for Naturela NPBC-V3M-1

  • Page 1 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 Electronic Pellet Burner Controller NPBC-V3M-1 3.3a/3.2 OFTWARE VERSION User Manual / version 2.6 http://www.naturela-bg.com/en/ page 1 of 28...
  • Page 2 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 HANGES IN THE USER MANUAL OR IN THE CONTROLLER S SOFTWARE User manual Changes Page version The software version is changed to 3.0/3.0 Different control logic of the circulation pumps of the installations.
  • Page 3 NPBC-V3M-1 is able to control an optional internal auger motor that forwards the pellets inside the burner. The controller runs two blowers: one that provides the air to the burning chamber and the other one is an additional fan, for example, for taking out the exhaust gases from the boiler, if necessary.
  • Page 4 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 NPBC-V3M ECHANISMS AND SENSORS THAT COULD BE CONNECTED TO  Electric feed screw motor to transfer pellets from the bunker to the burner (power up to 180W)  Electric internal auger motor to forward the fuel to the burning area (power up to 180W) ...
  • Page 5 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 User Manual / version 2.6 http://www.naturela-bg.com/en/ page 5 of 28...
  • Page 6 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 User Manual / version 2.6 http://www.naturela-bg.com/en/ page 6 of 28...
  • Page 7 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 XPLOITATION INSTRUCTIONS Main screen has the following view: Heating installation Internal screw motor Work phase Work mode Feed screw motor Boiler temperature Flame indicator Air fan Additional information Clock Press the F button to switch the work mode or to turn off the burner: Check sign ▲...
  • Page 8 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 Automatic work mode ( Auto ): By selecting this mode, a choice for the external installation, which is going to be heated by the boiler, appears: Work modes with external installations: CH Priority – only the building heating installation works. The circulation pump turns on •...
  • Page 9 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 works unconditionally. Parallel Pumps – both installations work: for heating and for hot water. The DHW circulation • pump works until the water heater reaches the set temperature in the menu DHW Setup. The...
  • Page 10 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 Programming mode for intervals of the day when boiler's work is allowed ( Programme ): If you decide that there is no need for the boiler to work twenty four hours, you can use the options for limitation of the work time in this mode.
  • Page 11 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 General information for operating with the controller : When the controller’s screen is in base position, by pressing the ▲ (+) or ▼(-) you enter in a mode for changing the temperature. Confirm the settings by pressing the Enter) button or automatically by pressing no buttons for 6 seconds.
  • Page 12: Working Method

    Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 View of the screen when a problem is registered: Sign for a problem in the controller Description of the problem/problems If there are any errors the current additional information switches with the error message and a sign E appears on the top right corner of the screen.
  • Page 13 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 5. After detecting the burning fire, there is an option to wait for the first dose of pellets to completely burn out, without feeding a new portion for a certain time. This might be set from the menu Initial burning.
  • Page 14: User Settings

    Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 procedure, blower's speed for the cleaning and the duration of the procedure. During this cleaning procedures the pellet feeding doesn't stop. If this cleaning method is unnecessary, it could be deactivated by setting the duration of the procedure (middle row in the menu Interm.
  • Page 15: Factory Settings

    Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 conditions must be implemented, as well: the controller must be working in DHW Priority, Parallel • pumps or Summer mode the temperature of the water in the boiler must be above 35 •...
  • Page 16 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 The following pressing the Enter button forwards to the first screen with factory settings. Browse the ▲ ▼ menus by pressing the arrow buttons: forwards to the next menu and returns to the previous. If you want to change the parameters in the currently displayed menu, press the Enter button again.
  • Page 17 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 Cleaning on Stop – set the work time for the main (Fan) and the additional (Cleaner) air fan for the cleaning cycle after extinction. These settings also apply for the intermediate automatic cleanings.
  • Page 18 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 Waiting for the first dose of fuel to burn out – Initial Burning – After detecting that the pellets are burning, the controller can wait for the fire to get steady. During this initial burning, no new pellets are fed and only the air fan and the exhaust fan work.
  • Page 19 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 level - Setup - adjust the work mode for 2 power level. Set the active time of the auger when loading a portion of pellets, the cycle time before loading a new portion of pellets and the speed of the fans.
  • Page 20 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 Suspend Time – adjust the maximum duration for maintaining the fire. If there is no need for increasing the power for longer than the time set in this setting, the burner turns off.
  • Page 21 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 Automatic clean up - Auto Clean Setup – The burner has an option for Automatic cleaning procedures. During these procedures, the burner turns off, cleans itself and automatically turns on again. The parameter in this menu indicates the burning time between the automatic cleaning procedures.
  • Page 22 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 Delay for the Cleaner motor – Cleaner – This menu sets a delay time after every cleaning procedure which uses the FC output. The delay time is equal to the active time of the FC output. For example, if you use this output for a mechanical actuator, during the cleaning procedures it will be supplied with power to push out the ashes.
  • Page 23 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 Maximum temperature - Set Temperature – adjust the upper limit of the range for the boiler’s temperature Safety Setup – A high temperature sensor pt100 monitors the temperature of the exhaust gases. The parameter Warn sets the value (in Celsius), above which the controller displays a warning message Cleanup.
  • Page 24 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 Test turning on of the rest of the outputs – Test Outputs – When a row is checked, power is supplied to this output for test purposes. User Manual / version 2.6 http://www.naturela-bg.com/en/...
  • Page 25 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 NPBC-V3M / NPBC-V4T-1 ETUP PARAMETERS RANGE FOR Setup Menu Parameter Unit Default Set Temp °C CH Setup Hysteresis °C Set Temp °C DHW Setup Hysteresis °C Contrast Contrast level seconds Cleaning on Start...
  • Page 26 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 Fan column 1 speed level Fan column 2 speed level Feed seconds 25.0 Cycle seconds 2nd Burn Level Setup Fan column 1 speed level Fan column 2 speed level Feed seconds 25.0...
  • Page 27 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 NPBC_Monitor.exe NPBC-V3M monitoring software User Manual / version 2.6 http://www.naturela-bg.com/en/ page 27 of 28...
  • Page 28 Electronic pellet burner controller - NPBC-V3M-1 / NPBC-V4T-1 NPBC_M ETTING ALL PARAMETERS WITH ONITOR User Manual / version 2.6 http://www.naturela-bg.com/en/ page 28 of 28...