YASKAWA SI-M3/V Installation Manual page 26

Ac drive-v1000 option componet
Table of Contents

Advertisement

5 Installation Procedure
Connection Diagram
Figure 18
CompoNet Master
Relay Terminal Block
<1> The ground wire provided in the option shipping package must be connected during
installation.
14.
Attach the option cover by aligning the tabs with the mounting holes, seat the front
cover into place, and tighten the screw on the front.
Figure 19
Note: Take proper precautions when wiring the option so that the front covers will easily fit back onto
the drive. Make sure no cables are pinched between the front covers and the drive when
replacing the covers.
Note: A replacement safety label is provided when using the drive in areas that may require displaying
warning information in Japanese or Chinese. This label can be placed over the English and
French warnings on the option cover.
15.
Set drive parameters in
26
Power
CompoNet Cable
(Red)
(White)
or
(Blue)
(Black)
Figure 18 Wiring Diagram
Figure 19 Attach the Option Cover
Table 9
YASKAWA ELECTRIC TOBP C730600 54A V1000 Option CompoNet Installation Manual
R
S
T
V1000
CN5
FE
SI-M3/V
BS+
BDH
BDL
BS-
Line up tabs
for proper option performance.
U
V
M
Motor
W
<1>

Advertisement

Table of Contents
loading

Table of Contents