Setting
0
1 - 99
Parameter 4: Light Threshold
Setting the illumination threshold to turn on the light. When the event triggered and the environment illumination lower then the threshold, the device will turn
on the light. 0 means turn off illumination detected function. And never turn on the light.
Notice: In none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value.
Size: 1 Byte, Default Value: 99
Setting
0
1 - 100
Parameter 5: Operation Mode
Operation mode. Using bit to control.
Size: 1 Byte, Default Value: 0
Setting
1
2
4
8
16
32
64
128
Parameter 6: Mult-Sensor Function Switch
Multisensor function switch. Using bit to control.
Size: 1 Byte, Default Value: 4
Setting
1
2
4
8
16
32
64
128
Parameter 7: Customer Function
Customer function switch, using bit control.
Size: 1 Byte, Default Value: 4
Setting
1
2
4
8
16
Description
disable the PIR motion.
1 means the lowest sensitivity, 99 means the highest sensitivity. High sensitivity means can detected long
distance, but if there is more noise signal in the environment, it will re-trigger too frequency.
Description
turn off illumination detected function.
1 means darkest. 99 means brightest. 100 means turn off illumination detected function. And always turn on the
light.
Description
Reserve.
1 means test mode, 0 means normal mode. Notice: This bit only effect by the DIP Switch setting to "customer
mode", otherwise it decides by DIP Switch setting to Test or Normal Mode
Reserve.
Setting the temperature scale. 0: Fahrenheit, 1:Celsius
Disable the illumination report after event triggered. (1:Disable, 0:Enable)
Disable the temperature report after event triggered. (1:Disable, 0:Enable)
Reserve.
Disable the back key release into test mode. (1:Disable, 0:Enable)
Description
Reserve.
Disable PIR integrate Illumination to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable)
Reserve.
Reserve.
Reserve.
Reserve.
Reserve.
Reserve.
Description
Reserve.
Enable sending motion OFF report. (0:Disable, 1:Enable)
Enable PIR super sensitivity mode. (0:Disable, 1:Enable)
Reserve.
Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report.