Tubular motor:
GEIGER-SOLIDline
Motor control:
GEIGER-SoftPerfection-X01 (GU45...-E03)
for rolling shutters with stoppers and anti-lift device
Original-Montage- und
DE
Betriebsanleitung
Original assembly and
EN
operating instructions
Notice originale de montage
FR
et d'utilisation
Instrucciones originales de
ES
instalación y funcionamiento
Istruzioni originali di installazione
IT
e funzionamento
www.geiger.de
EN
1
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SOLIDline and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GEIGER SOLIDline

  • Page 1 Tubular motor: GEIGER-SOLIDline Motor control: GEIGER-SoftPerfection-X01 (GU45...-E03) for rolling shutters with stoppers and anti-lift device Original-Montage- und Betriebsanleitung Original assembly and operating instructions Notice originale de montage et d’utilisation Instrucciones originales de instalación y funcionamiento Istruzioni originali di installazione e funzionamento...
  • Page 2: Table Of Contents

    12. End position correction ............9 13. What to do if… ................9 14. Maintenance ................9 15. Declaration of conformity ............10 16. Technical data ................. 11 17. Notes on waste disposal ............11 Gerhard Geiger GmbH & Co. KG | 100W0520 V000 0219...
  • Page 3: Geiger-Softperfection-X01: Special Features

    Ready! Plug & Play! Cloth protection with the Soft-System • The Geiger soft position ensures that the hanging stops a few millime- tres before reaching the end position. The hanging is thus optimally protected. Two exceptions: the programming runs and the reference runs after 50 cycles.
  • Page 4: General Information

    4. Intended use The tubular motors of the model range SOLIDline (GU45...-E03) are designed for the operation of rolling shutters with anti-lift device and stoppers The motors may not be used for the operation of roller grilles, garage doors, furniture and lifting tools.
  • Page 5: Safety Instructions

    (e.g. isolator). f The motor tube can get very hot during prolonged use. When working on the unit, do not touch the tube before it has cooled down. www.geiger.de...
  • Page 6: Safety Instructions For Assembly

    A plug for the disconnection of the motor from the power supply must be accessible after installation. f Damaged connecting cables must be replaced by Geiger connecting cables of the same type. f The device must be mounted as described in the installation instructions. Fixations shall not be made with adhesives since they are regarded as unreliable.
  • Page 7: Installation Instructions

    The bearing locks into place. To loosen, turn the spring washer. In order to adjust the end positions, a rolling shutter system with upper end stop and anti-lift device is required. The GEIGER-SOLIDline motor is suitable for shaft diameters from 50 mm! www.geiger.de...
  • Page 8: Information For The Specialist Electrician

    1 sec 5 sec 1 sec 5 sec 1 sec 5 sec Please note: a break of at least 5 seconds must be respected between the different runs. 3. DONE! Gerhard Geiger GmbH & Co. KG | 100W0520 V000 0219...
  • Page 9: Obstacle Recognition

    After running several times, • The motor became too hot and has the motor breaks down and switched off. no longer responds. Try it again after a cooling time of about 15 min. 14. Maintenance The drive is maintenance-free. www.geiger.de...
  • Page 10: Declaration Of Conformity

    Gerhard Geiger GmbH & Co. KG Schleifmühle 6 | D-74321 Bietigheim-Bissingen Phone +49 (0) 7142 9380 | Fax +49 (0) 7142 938 230 | info@geiger.de | www.geiger.de Sitz Bietigheim-Bissingen | Amtsgericht Stuttgart HRA 300591 | USt-IdNr. DE145002146 Komplementär: Geiger Verwaltungs-GmbH | Sitz Bietigheim-Bissingen | Amtsgericht Stuttgart HRB 300481 Geschäftsführer: Roland Kraus | WEEE-Reg.-Nr.
  • Page 11: Technical Data

    T = -15°C .. +70°C / dry and non-condensing place Humidity SOLIDline-COM + 3,5 mm / SOLIDline-SOC: + 3 mm / SOLIDline-SIL: ± 0 mm (without trunnion) The average sound pressure level data are intended for guidance only. The values were determined by Geiger at a distance of 1 m, with a hanging motor at idle speed and averaged over 10 seconds.
  • Page 12: En Gerhard Geiger Gmbh & Co. Kg | 100W0520 En V000

    They will be happy to assist you. Gerhard Geiger GmbH & Co. KG Schleifmühle 6 | D-74321 Bietigheim-Bissingen T +49 (0) 7142 9380 | F +49 (0) 7142 938 230 info@geiger.de | www.geiger.de Gerhard Geiger GmbH & Co. KG | 100W0520 V000 0219...