GEIGER SOLIDline Series Original Assembly And Operating Instructions

Motor for rolling shutters with anti-lift device and stoppers

Advertisement

Tubular motor:
GEIGER-SOLIDline
Motor control:
GEIGER VariousWireless/X01 (GU45..F03)
for rolling shutters with anti-lift device and stoppers
Original-Montage- und
DE
Betriebsanleitung
Original assembly and
EN
operating instructions
Notice originale de montage
FR
et d'utilisation
Instrucciones originales de
ES
instalación y funcionamiento
Istruzioni originali di installazione
IT
e funzionamento
www.geiger.de
EN
1
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SOLIDline Series and is the answer not in the manual?

Questions and answers

Summary of Contents for GEIGER SOLIDline Series

  • Page 1 Tubular motor: GEIGER-SOLIDline Motor control: GEIGER VariousWireless/X01 (GU45..F03) for rolling shutters with anti-lift device and stoppers Original-Montage- und Betriebsanleitung Original assembly and operating instructions Notice originale de montage et d’utilisation Instrucciones originales de instalación y funcionamiento Istruzioni originali di installazione e funzionamento www.geiger.de...
  • Page 2: Table Of Contents

    1. General information Dear customer, By purchasing a GEIGER motor you have decided on a quality product from GEIGER. Thank you very much for your decision and the confidence placed in us. Before you put this drive into operation please observe the following safety instructions. It serves for the prevention of danger and for the avoidance of personal injury and damage to property.
  • Page 3: Intended Use

    GU 45 Motor control Torque in Nm Motor diameter GEIGER universal drive 4. Safety instructions ATTENTION: Important safety instructions. For personal safety, it is important to follow these instructions. Please keep these instructions for future reference. f Do not allow children to play with stationary controls. Keep remote controls away from children.
  • Page 4: Safety Instructions For Assembly

    A plug for the disconnection of the motor from the power supply must be accessible after installation. f Damaged connecting cables must be replaced by GEIGER connecting cables of the same type. f The device must be mounted as described in the installation instructions. Fixations shall not be made with adhesives since they are regarded as unreliable.
  • Page 5: Installation Instructions

    The bearing locks into place. To loosen, turn the spring washer. In order to adjust the end positions, a rolling shutter system with upper end stop and anti-lift device is required. The GEIGER-SOLIDline motor is suitable for shaft diameters from 50 mm! www.geiger.de...
  • Page 6: Information For The Specialist Electrician

    Switch on the power supply. After 2 seconds, the motor mains confirms with 2 x “click-click” that the learning is completed. Up to 3 transmitters can be programmed that way. Gerhard Geiger GmbH & Co. KG | 100W1576 V000 0818...
  • Page 7: Learning / Deleting The Transmitter

    5 sec. until the motor confirms the deleting of the transmitter with 1 x “click-click”. Please note: You can only delete all transmitters and sensors together. max. 15 cm It is not possible to delete an individual transmitter / sensor. about 5 sec. www.geiger.de...
  • Page 8: Activate The Learning Mode For End Positions

    1 sec 5 sec 1 sec 5 sec 1 sec 5 sec 1 sec 5 sec Please note: a break of at least 5 seconds must be respected between two operations. Gerhard Geiger GmbH & Co. KG | 100W1576 V000 0818...
  • Page 9: Setting Of The End Positions

    Stop the rolling shutter from UP or DOWN movement and click keep key pressed for about 5 sec. – the motor responds with 1 x “click-click” after 3 sec. – until the motor confirms the deletion (3 x “click-click”). min. 1,5 m about 5 sec. www.geiger.de...
  • Page 10: Grouped Control

    3. Actuate key 3 sec. at close range to activate the learning mode of rolling shutter B. 4. Actuate key 1 sec. at close range to program the transmitter of rolling shutter B. 2 3 4 5 6 Same operation for three or more rolling shutters. Gerhard Geiger GmbH & Co. KG | 100W1576 V000 0818...
  • Page 11: Deactivation Of The Close Range Function

    To deactivate the close-range function, move the selected rolling shutter to the upper end position, push the UP key and keep it pushed for about 5 seconds until the motor confirms (2 x “click-click”). The motor must be briefly disconnected from the mains to activate the close-range function. www.geiger.de...
  • Page 12: Transmitters

    For stopping the travel movement a short key press in the opposite direction is sufficient. Should a sun-wind sensor be integrated into the system, the end positions are started in automatic mode (sun-on). Gerhard Geiger GmbH & Co. KG | 100W1576 V000 0818...
  • Page 13: Obstacle Recognition

    If, due to temperature changes, modified winding behaviour should arise and the hangings should run against the stop, an immediate end position correction takes place. In addition, the counter for the end position correction is started afresh. www.geiger.de...
  • Page 14: What To Do If

    • The learning mode time is over (30 minutes). In order to activate the short range, disconnect the motor from the power supply for about 3 seconds. 20. Maintenance The drive is maintenance-free. Gerhard Geiger GmbH & Co. KG | 100W1576 V000 0818...
  • Page 15: Declaration Of Conformity

    Gerhard Geiger GmbH & Co. KG Schleifmühle 6 | D-74321 Bietigheim-Bissingen Phone +49 (0) 7142 9380 | Fax +49 (0) 7142 938 230 | info@geiger.de | www.geiger.de Sitz Bietigheim-Bissingen | Amtsgericht Stuttgart HRA 300591 | USt-IdNr. DE145002146 Komplementär: Geiger Verwaltungs-GmbH | Sitz Bietigheim-Bissingen | Amtsgericht Stuttgart HRB 300481 Geschäftsführer: Dr.
  • Page 16: Technical Data

    The average sound pressure level data are intended for guidance only. The values were determined by GEIGER at a distance of 1 m, with a hanging motor at idle speed and averaged over 10 seconds. There is no reference to any specific test standard.

This manual is also suitable for:

Gu4510Gu4540Gu4550Gu4520Gu4530

Table of Contents