Advertisement

Quick Links

Tubular motor:
GEIGER-SOLIDline (GU45.. F04)
Motor control:
GEIGER Sun AIR
for cassette awnings
Original-Montage- und
DE
Betriebsanleitung
Original assembly and
EN
operating instructions
Notice originale de montage
FR
et d'utilisation
Instrucciones originales de
ES
instalación y funcionamiento
Istruzioni originali di installazione
IT
e funzionamento
www.geiger.de
EN
1
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SOLIDline and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GEIGER SOLIDline

  • Page 1 Tubular motor: GEIGER-SOLIDline (GU45.. F04) Motor control: GEIGER Sun AIR for cassette awnings Original-Montage- und Betriebsanleitung Original assembly and operating instructions Notice originale de montage et d’utilisation Instrucciones originales de instalación y funcionamiento Istruzioni originali di installazione e funzionamento www.geiger.de...
  • Page 2: Table Of Contents

    1. General information Dear customer, By purchasing a GEIGER motor you have decided on a quality product from GEIGER. Thank you very much for your decision and the confidence placed in us. Before you put this drive into operation please observe the following safety instructions. It serves for the prevention of danger and for the avoidance of personal injury and damage to property.
  • Page 3: Intended Use

    3. Intended use The motors of the model range SOLIDline Sun AIR with AIR radio technology are designed exclusively for the operation of cassette awnings. The motors may not be used for the operation of roller grilles, garage doors, furniture and lifting tools.
  • Page 4: Safety Instructions For Assembly

    A plug for the disconnection of the motor from the power supply must be accessible after installation. f Damaged connecting cables must be replaced by GEIGER connecting cables of the same type. f The device must be mounted as described in the installation instructions. Fixations shall not be made with adhesives since they are regarded as unreliable.
  • Page 5: Installation Instructions

    – Place the motor into the existing engine bearer and lock – Place the motor in a compatible engine bearer with clip system and lock with spring or rotating lever The GEIGER SOLIDline motor is suitable for shaft diameters from 50 mm. www.geiger.de...
  • Page 6: Information For The Specialist Electrician

    Connecting cables with plug connectors of the Hirschmann Company are tested and approved with couplings of the Hirschmann Company. 8. Operating modes of the GEIGER SOLIDline AIR The motor can be operated in two ways: • Individual control: the motor is operated with a handheld or wall transmitter •...
  • Page 7: Programming/Deleting The Handheld Or Wall Transmitter

    Deactivate the learning mode To deactivate the learning mode, press the LEFT and RIGHT keys simultaneously for about 4 seconds until the channel 1 2 3 4 5 6 LED stops blinking. The learning mode is deactivated. approx. 4 sec. www.geiger.de...
  • Page 8: Learning Mode For End Positions

    UP and DOWN keys of the transmitter for 1 2 3 4 5 6 about 4 seconds until the channel LEDs stop blinking. The learning mode for end positions is now deactivated. approx. 4 sec. Gerhard Geiger GmbH & Co. KG | 100W1582 V000 0518...
  • Page 9: Setting The End Positions

    To deactivate the learning mode for end positions, press 1 2 3 4 5 6 simultaneously the UP and DOWN keys of the transmitter for about 4 seconds until the channel LEDs stop blinking. approx. 4 sec. The learning mode for end positions is now deactivated. www.geiger.de...
  • Page 10: Intermediate Position

    With a short key press of less than 1.5 seconds, the intermediate position is travelled to. For stopping the travel movement a short key press in the opposite direction is sufficient or use stop key. Gerhard Geiger GmbH & Co. KG | 100W1582 V000 0518...
  • Page 11: Connection To Loxone Miniserver

    14. Connection to Loxone Miniserver Conditions In order to integrate the SOLIDline AIR in your Loxone system, a Miniserver Go or a Miniserver with Air Base Extension must be operational. More information under: www.loxone.com/help/miniserver Commissioning in Loxone Config In order to learn the GEIGER SOLIDline AIR, the learning mode must be activated. The learning mode is automatically activated for 30 minutes when the power supply is switched off and then on again.
  • Page 12: Obstacle Recognition

    Disconnect the motor and repeat the operation The motor jerks during starting (start, • The motor is in learning mode. The stop, start). minimum travel distance might have been under passed. Gerhard Geiger GmbH & Co. KG | 100W1582 V000 0518...
  • Page 13: Declaration Of Conformity

    Gerhard Geiger GmbH & Co. KG Schleifmühle 6 | D-74321 Bietigheim-Bissingen Phone +49 (0) 7142 9380 | Fax +49 (0) 7142 938 230 | info@geiger.de | www.geiger.de Sitz Bietigheim-Bissingen | Amtsgericht Stuttgart HRA 300591 | USt-IdNr. DE145002146 Komplementär: Geiger Verwaltungs-GmbH | Sitz Bietigheim-Bissingen | Amtsgericht Stuttgart HRB 300481 Geschäftsführer: Dr.
  • Page 14: Technical Data

    The average sound pressure level data are intended for guidance only. The values were determined by GEIGER at a distance of 1 m, with a hanging motor at idle speed and averaged over 10 seconds. There is no reference to any specific test standard.
  • Page 15 www.geiger.de...
  • Page 16: En Gerhard Geiger Gmbh & Co. Kg | 100W1582 En V000

    They will be happy to assist you. Gerhard Geiger GmbH & Co. KG Schleifmühle 6 D-74321 Bietigheim-Bissingen Telephone: +49 (0) 7142 938-0 Telefax: +49 (0) 7142 938-230 E-Mail: info@geiger.de Internet: www.geiger.de Gerhard Geiger GmbH & Co. KG | 100W1582 V000 0518...