B.9.2 European approvals
Note
A certified isolating amplifier to IEC 60947-5-6 is required
for intrinsic safety approvals if the NAMUR electronics is
used in a hazardous area installation (see below).
A certified intrinsically safe barrier is required for intrinsic
safety if the 8/16 mA electronics is used in a hazardous area
installation (see below).
ATEX flameproof and dust proof approval
E1
Certificate: Sira 05ATEX1129X
Flameproof and dust proof:
ATEX Marking
II 1/2 G D
Ex db IIC T6...T2 Ga/Gb
Ex tb IIIC T85 °C...T265 °C Db
See also
"Instructions specific to hazardous area installations
(E1 and E7)" on page
64.
ATEX intrinsically safe approval
I1
Certificate: Sira 05ATEX2130X
Intrinsic Safety for gas and dust atmospheres:
ATEX Marking
II 1 G D
Ex ia IIC T5...T2 Ga
Ex ia IIIC T85 °C...T265 °C Da
See also
"Instructions specific to hazardous area installations
(I1 and I7)" on page
62.
B.9.3 International approvals
Note
A certified isolating amplifier to IEC 60947-5-6 is required
for intrinsic safety approvals if the NAMUR electronics is
used in a hazardous area installation (see below).
A certified intrinsically safe barrier is required for intrinsic
safety if the 8/16 mA electronics is used in a hazardous area
installation (see below).
INMETRO flameproof and dust proof approval
E2
Certificate Number: UL-BR 18.0284X
Flameproof and dust proof:
Ex db IIC T6...T2 Ga/Gb, Ex tb IIIC T85°C...T265°C Db
See specific conditions of use for the temperature class and
maximum surface temperature for dust (T**°C) that are
applicable to the relevant ambient and process temperatures.
See also
"Instructions specific to hazardous area installations
(E1 and E7)" on page
64.
Product Certifications
Specific conditions of use:
1. The temperature class and the maximum surface
temperature for dust (T**°C) are defined by the appropriate
ambient temperature and process temperature. See
"Temperature" on page 28 for details.
2. When coated with a non-standard paint, the enclosure is
non-conducting and may generate an ignition-capable level
of electrostatic charges under certain extreme conditions.
The user should ensure that the equipment is not installed in
a location where it may be subjected to external conditions,
which might cause a build-up of electrostatic charges on
non-conducting surfaces. Additionally, cleaning of the
equipment should be done only with a damp cloth.
INMETRO intrinsically safe approval
I2
Certificate Number: UL-BR 18.0441X
Intrinsically safe for gas and dust atmospheres:
Ex ia IIC T5...T2 Ga, Ex ia IIIC T85°C...T265°C Da
See specific conditions of use for the temperature class and
maximum surface temperature for dust (T**°C) that are
applicable to the relevant ambient and process temperatures.
Security parameters
NAMUR:
Ui = 15 V / Ii = 32 mA / Pi = 0,1 W / Ci = 12 nF / Li = 0,06 mH
8/16 mA:
Ui = 30 V / Ii = 93 mA / Pi = 0,65 W / Ci = 12 nF / Li = 0,035 mH
See also
"Instructions specific to hazardous area installations
(I1 and I7)" on page
62.
Specific conditions of use:
1. Under certain extreme circumstances, the non-metallic parts
of the equipment may be capable of generating an
ignition-capable level of electrostatic charge. The equipment
shall only be cleaned with a damp cloth.
2. The temperature class is defined by the appropriate ambient
temperature and the process temperature.
National Supervision and Inspection Centre for Explosion
Protection and Safety Instrumentation (NEPSI)
flameproof approval
E3
Certificate: GYJ101373
Flameproof and dust proof:
Ex d IIC T6~T2
DIP A21 T
(T85 °C ~ 265 °C) IP6X
A
See
"Instructions specific to hazardous area installations (E3)"
on page
67.