Advertisement

Quick Links

Models 714E, 1414E, 1818E & 2020E
Dean, a member of the Commercial Food Equipment Service Association, recommends using
CFESA Certified Technicians.
Price: $6.00
24-Hour Service Hotline 1-800-551-8633
819-5867

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2020E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dean 2020E

  • Page 1 Models 714E, 1414E, 1818E & 2020E Dean, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians. Price: $6.00 24-Hour Service Hotline 1-800-551-8633 819-5867...
  • Page 2 PLEASE READ ALL SECTIONS OF THIS MANUAL AND RETAIN FOR FUTURE REFERENCE. This product has been certified as commercial cooking equipment and must be installed by professional personnel as specified. We suggest installation, maintenance and repairs should be performed by your local Factory Authorized Service Center.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS 1. DESCRIPTION AND SPECIFICATIONS.............1 2. PRE-INSTALLATION..................2 3. RECEIVING AND INSTALLING THE FRYER ..........2 4. INITIAL START-UP..................3 5. DAILY OPERATION ..................4 6. CLEANING & MAINTENANCE..............5 7. TROUBLESHOOTING..................6 8. RECOMMENDED SPARE PARTS/PARTS LIST .........7 9. FACTORY SERVICE & PARTS ORDERING..........11 10.
  • Page 4: Description And Specifications

    APPROX. SHIPPING 115# 153# 190# 200# valve prohibits element operation with the Note: 1818E and 2020E are also available in 13.5 KW drain valve even partially open. models. RATING PLATE: This is riveted to the inside right-hand corner of VESSEL CONSTRUCTION: the fryer door.
  • Page 5: Pre-Installation

    2. PRE-INSTALLATION 3. RECEIVING & INSTALLING THE FRYER GENERAL: Installation of any heavy-duty electrical UNPACKING: appliance should be made by a licensed Check that the container is upright. Use electrician. outward prying - no hammering - to remove the carton. Check the fryer(s) for visible damage; if STANDARDS: such damage has occurred, do not refuse shipment, but contact the carrier and file the...
  • Page 6: Initial Start-Up

    Close the drain-valve completely and remove LEVELING: the crumb screen. a) A carpenter's spirit level should be placed across the top of the fryer and Make sure the screws holding the thermostat the unit leveled both front-to-back and and limit control sensing bulbs into the vessel side-to-side.
  • Page 7: Daily Operation

    c) When the fryer vessel is filled and the frying compound temperature will shortening melted, replace the crumb stabilize and be ready for production. screen. USE OF THE FRYER: d) Before starting operation, turn For optimum results, the following general operating thermostat to the probable information is offered.
  • Page 8: Cleaning & Maintenance

    valve at the filter to promote draining of the This will void the warranty for your filter, return lines into the filter pan. hasten filter pump failure, and could cause accidents if water mixes with hot If using solid shortening, always make sure the oil.
  • Page 9: Troubleshooting

    L2; if defective, replace FACTORY APPROVAL MUST BE OBTAINED the part. PRIOR TO ANY WARRANTY WORK BEING DONE OR DEAN INDUSTRIES CANNOT BE 5) Check the wiring to the temperature HELD RESPONSIBLE. controller. 7.1 If the elements will not turn on and there 7.2 Poor temperature control on the cold...
  • Page 10: Recommended Spare Parts/Parts List

    7.3 Poor temperature control on the hot 7.5 TEMPERATURE ADJUSTMENT: side; excessive temperature overshoot An additional feature of the "Thermatron" during warm-up; over heating, controller is a temperature fine-tune adjustment. scorching; high-limit switch must be If the actual temperature of the cooking oil reset often.
  • Page 11 PARTS LIST COOL ZONE ELECTRIC FRYERS MODELS 714E, 1414E, 1818E, 2020E...
  • Page 12 PARTS LIST COOL ZONE ELECTRIC FRYERS MODELS 714E, 1414E, 1818E, 2020E ITEM DESCRIPTION 714E 1414E 1818E 2020E Structural panel, L/H 12-0160-1 (P) 07-0031 20-0065 12-0159-1 (S/S) Structural panel, R/H 12-0160-2 (P) 07-0032 20-0064 12-0159-2 (S/S) Vessel top spacer 14-0598 07-0024...
  • Page 13 PARTS LIST COOL ZONE ELECTRIC FRYERS MODELS 714E, 1414E, 1818E, 2020E ITEM DESCRIPTION 714E 1414E 1818E 2020E Circuit breaker mounting plate 1594 1594 1594 1594 Circuit breaker 1593 1593 1593 Contactor 1368 1368 1368 1368 Thermatron mounting plate 07-0127 14-0453...
  • Page 14 PARTS LIST COOL ZONE ELECTRIC FRYERS MODELS 714E, 1414E, 1818E, 2020E Thermatron Controllers: THERMATRON CONTROLLER CHART DESCRIPTION 714E 1414E 1818E 2020E Thermatron Retro Kit, 208V 14714-1 14715-1 18149-3 18149-3 Thermatron Retro Kit, 240V 14714-2 14715-2 18149-4 18149-4 Thermatron Retro Kit, 208V with...
  • Page 15: Factory Service & Parts Ordering

    9. FACTORY SERVICE & PARTS ORDERING SERVICE PROBLEMS: Call the number on the cover of this booklet for the location of your nearest Maintenance & Repair Center or contact the factory direct. Always give the model and serial number of your fryer.
  • Page 16: Specifications

    14"x14" 153/15 (394) (1143) 1818E 70-85 lbs 20" (508) 33" (838) 45" (1143) 35" (889) 1-1/4" 20" 18"x18" 190/28 2020E 95-110 lbs 21" (533) 33" (838) 45" (1143) 35" (889) 1-1/4" 20" 20"x20" 200/35 POWER REQUIREMENTS: MODEL INPUT SINGLE PHASE...
  • Page 17: Wiring Diagrams

    11. WIRING DIAGRAMS...
  • Page 21: Limited Warranty

    Dean will not be responsible for problems found to be caused by use of a non-OEM part or replacement of a defective part with other than a factory OEM part.