Radio energy sensor, 1-gang intermediate plug
Measuring status:
time synchronisation active
Measuring status:
Acknowledged
Measuring status:
no alarm
Voltage
Current
Effective output
Idle output
Apparent output
Absolute effective energy
Effective energy
i The value can be updated using the arrow next to the display values.

5.3 Troubleshooting

Negative effective output or energy values are displayed.
Cause: This is an energy source, e.g. a photovoltaic system, feeding in energy.
i If negative idle power values are displayed, this is a capacitive idle power. Positive values
show an inductive idle power.
5.4 Accessories
DRA server

5.5 Warranty

The warranty is provided in accordance with statutory requirements via the specialist trade.
Please submit or send faulty devices postage paid together with an error description to your
responsible salesperson (specialist trade/installation company/electrical specialist trade). They
will forward the devices to the Gira Service Center.
32582202
10499462
Not used.
Not used.
Not used.
Displays the current voltage value.
Displays the current current value.
Displays the current effective output.
Displays the current idle output.
If negative values are displayed, this is a
capacitive idle power. Positive values show an
inductive idle power.
Displays the current apparent output.
Displays the current absolute effective energy.
If negative values are displayed, then effective
energy is fed in, e.g. via a photovoltaic
system.
Displays the cumulated effective energy.
Counter status can be set via settings window.