Gira 5472 02 Operating Instructions Manual page 5

Radio energy sensor, 1-gang intermediate plug

Advertisement

eNet
Radio energy sensor, 1-gang intermediate plug
Transmission interval
Rel. threshold value, effective
output
Abs. threshold value, effective
output
Suppression length, effective
output
Averaging length
Information window
During channel selection in the Information window, the following values are displayed.
Display value
Measuring status:
value is real/
out of service
Measuring status:
no fault/
value is corrupted due to failure
Measuring status:
in commission
32582202
10499462
1 ... 60 min
Basic setting: 15 min
1 ... 50 %
Basic setting: 10 %
0 ... 2000 W
Basic setting: 1 W
0 ms ... 300 s
Basic setting: 0 ms
0.2 ... 300 s
Basic setting: 1 s
Explanations
value is real: Device being operated
out of service: Device error
no fault: Measurement active
value is corrupted due to failure: The sensor is
not supplying valid measured values.
Not used.
13.03.2014
The current consumption data
is transmitted at the interval
set here at the latest. Changes
to the effective output cause
fresh transmission, however
only after one minute at the
earliest.
The transmission of
consumption data can be
coupled to the change in
effective output. The basis is
always the most recently
transmitted effective output
value. If the percentage
change entered here is
exceeded, then all the
measured values are resent.
A lower threshold value of the
effective output can be
entered here, to avoid
frequent transmission in the
lower power range. Event-
controlled transmission is only
active above this threshold
value.
Triggers for event-controlled
transmission are often switch-
on and switch-off operations.
In order to avoid incorrect
measured values due to
switch-on peaks, this
parameter can be used to
enter a suppression period.
The measured values are only
transmitted if the effective
output is still above or below
the relative threshold value
after the set time.
In the case of effective output,
it is not the current value
which is transmitted, as with
other measured values, but
the average value. It is
possible to set the period for
average value formation here.
5/7