Wireless energy sensor, 1-gang Mini
Information window
During channel selection in the Information window, the following values are displayed.
Display value
Voltage
Current
Effective power
Reactive power
Apparent power
Absolute active energy
Active energy
i The value can be updated using the arrow next to the display values.

5.3 Troubleshooting

Negative effective output or energy values are displayed.
Cause 1: This is an energy source, e.g. a photovoltaic system, feeding in energy.
Cause 2: The energy sensor is connected in reverse polarity.
Connect the energy sensor with the correct polarity.
i If negative reactive power values are displayed, this is a capacitive idle power. Positive
values show an inductive reactive power.
5.4 Accessories
Installation adapter Mini housing
eNet Server
5.5 Conformity
Gira Giersiepen GmbH & Co. KG hereby declares that the radio system type
Order No. 5471 00
corresponds to the directive 2014/53/EU. You can find the full article number on the device. The
complete text of the EU Declaration of Conformity is available under the Internet address:
www.gira.de/konformitaet

5.6 Warranty

The warranty follows about the specialty store in between the legal framework as provided for
by law
Please submit or send faulty devices postage paid together with an error description to your
responsible salesperson (specialist trade/installation company/electrical specialist trade). They
will forward the devices to the Gira Service Center.
32581512
10864964
Explanations
Displays the current voltage value.
Displays the current current value.
Displays the current effective power.
Displays the current reactive power.
If negative values are displayed, this is
capacitive reactive power. Positive values
show an inductive reactive power.
Displays the current apparent power.
Displays the current absolute active energy.
If negative values are displayed, then effective
energy is fed in, e.g. via a photovoltaic
system.
Displays the cumulated active energy. Meter
reading can be set via settings window.