Configuring The Mrp-Ring - Hirschmann RS20 Reference Manual

Web-based interface industrial ethernet switch
Hide thumbs Also See for RS20:
Table of Contents

Advertisement

Redundancy

6.1.2 Configuring the MRP-Ring

To configure an MRP-Ring, you set up the network to meet your require-
ments. For the ring ports, select the following basic settings in the Basic
Settings:Port Configuration dialog:
Bit rate
Autonegotiation
(automatic configuration)
Port
Duplex
Table 22: Port settings for ring ports
Note: Configure all the devices of the MRP-Ring individually. Before you
connect the redundant line, you must complete the configuration of all the de-
vices of the MRP-Ring. You thus avoid loops during the configuration phase.
Parameter
Meaning
Ring port X.X
Display in "Operation" field:
operation
forwarding: This port is switched on and has a link.
blocked: This port is blocked and has a link.
disabled: This port is switched off.
not connected: This port has no link.
Configuration
Deactivate the advanced mode if a device in the ring does not support the ad-
Redundancy
vanced mode for fast switching times. Otherwise you activate the advanced
Manager
mode.
(Ring Manag-
Note: All Hirschmann devices that support the MRP-Ring also support the ad-
er)
vanced mode.
Operation
When you have configured all the parameters for the MRP-Ring, you switch the
operation on here. When you have configured all the devices in the MRP-Ring,
you close redundant lines.
Ring Recov-
Select the desired value for the device for which you have activated the ring
ery
manager. Select 500 ms for the ring recovery if the ring stability does not meet
the requirements of your network.
Note: Settings in the "Ring Recovery" frame are ineffective for devices that are
not ring managers.
Table 23: MRP-Ring configuration
RM Web L2B
Release 5.0 04/09
100 Mbit/s
off
on
Full
6.1 Ring Redundancy
1000 Mbit/s
on
on
71