Hirschmann RS20 Reference Manual page 83

Web-based interface industrial ethernet switch
Hide thumbs Also See for RS20:
Table of Contents

Advertisement

Diagnosis
The events which can be selected are:
Name
Power supply ...
Temperature
ACA removal
Connection error
HIPER-Ring
Fan
Table 25: Device Status
Select "Generate Trap" in the "Trap configuration" field to activate the
sending of a trap if the device state changes.
Note: With non-redundant voltage supply, the device reports the absence of
a supply voltage. You can prevent this message by feeding the supply volt-
age over both inputs, or by switching off the monitoring
nal contact").
RM Web L2B
Release 5.0 04/09
Meaning
Monitor/ignore supply voltage(s).
Monitor/ignore temperature thresholds set
temperatures that are too high/too low
Monitor/ignore the removal of the ACA.
Monitor/ignore the defective link status of at least one port.
The reporting of the link status can be masked for each port by the
management
(see on page
monitored in the state on delivery.
Monitor/ignore the discard of the existing redundancy (in Ring Manager
mode).
State on delivery: ring redundancy is not monitored.
Monitor/ignore fan function (for devices with fan).
(see on page
25 „Port configuration"). Link status is not
(see on page
7.5 Device Status
16
„System")
for
84 „Sig-
83