Diagnosis

7.7 Alarms (Traps)

This dialog allows you to determine which events trigger an alarm (trap) and
where these alarms should be sent.
Select „Create entry".
In the „Address" column, enter the IP address of the management station
to which the traps should be sent.
In the „Enabled" column, you mark the entries which should be taken into
account when traps are being sent.
In the „Selection" frame, select the trap categories from which you want
to send traps.
The events which can be selected are:
Name
Meaning
Authentication
The device has rejected an unauthorized access attempt,
„SNMPv1/v2 Access Settings"), (see on page 80 „Port Mirroring").
Link Up/Down
At one port of the device, the link to a device connected there has been es-
tablished/interrupted.
Spanning Tree
The topology of the Rapid Spanning Tree has changed.
Chassis
Summarizes the following events:
– The status of a supply voltage has changed (see the System dialog).
– The status of the signal contact has changed.
To take this event into account, you activate "Create trap when status
changes" in the Diagnostics:Signal Contact 1/2 dialog.
– A media module was added or removed.
– The AutoConfiguration AdapterACA was added or removed.
– The temperature threshold was exceeded/not reached.
– The receiver power status of a port with an SFP module has changed (see
dialog Dialog:Ports:SFP Modules).
Redundancy
The redundancy status of the ring redundancy (redundant line active/inac-
tive) has changed.
Table 26: Trap categories