Redundancy
7.1.2 Configuring HIPER-Ring Version 2 (MRP
Draft)
Set up the network to meet your requirements.
Note: Before you connect the redundant line, you must complete the
configuration of HIPER-Ring Version 2.
You thus avoid loops during the configuration phase.
Note: Configure each HIPER-Ring device.
Select the Redundancy:HIPER-Ring dialog.
Select Version 2 (MRP Draft).
For each device, you enter the desired ring ports 1 and 2.
The following settings are required for the ring ports (select the Basic
Settings:Port Configuration dialog):
Bit rate
Autonegotiation
(automatic configuration)
Port
Duplex
Table 11: Port settings for ring ports
Note: When using 100 Mbit/s with twisted pair cables, avoid the combination
of autonegotiation "off" and cable crossing "automatic". Use crossover cables
with 100 Mbit/s.
74
100 Mbit/s
Off
On
Full
7.1 HIPER-Ring
1000 Mbit/s
On
On