6.

Technical Specifications/Certifications

6.1.

Technical Specifications

Weight (standard blower)
Working life of the battery
Operating temperature range
Storage temperature range
Air volume flow for OptimAir 3000
and OptimAir 3000EX
 Use of hoods
 Use of full face mask
Air volume flow for OptimAir 3000A
 Use of full face mask
OptimAir 3000
International protection class
according to DIN EN 60529
6.2.

Certifications

The product complies with the following directives, standards or standardisation
documents:
OptimAir 3000EX Directive 2014/34/EU (ATEX) :
OptimAir 3000
OptimAir 3000A
OptimAir 3000EX
The Declaration of Conformity can be found under the following link:
https://MSAsafety.com/DoC
GB
TECHNICAL SPECIFICATIONS/CERTIFICATIONS
Complete turbo filter device
(in combination with MSA
breathing connection and
filter)
Directive 2014/30/EU (EMC)
EN 61000-6-2
EN 61000-6-4
Directive 89/686/EC or
Regulation (EU) 2016/425,
respectively
EN 12941, EN 12942
OptimAir 3000, 3000A and 3000EX
approx. 1.28 kg
(with battery, without filters, without belt)
at least 4 hours (at maximum loading)
+5°C to +40°C
-5 °C to +50 °C,
max. 95% air humidity
approx. 130 l/min to 150 l/min
approx. 110 l/min
approx. 160 l/min to 185 l/min
IP 54
BVS 07 ATEX E 038
II 2G Ex ib IIA T4
II 2D Ex ibD 21 T130°C
:
IFA, Alte
Heerstraße 111,
D-53757 St. Augustin,
Notified Body 0121