Start-Up; General Rules For Making Adjustments To The Spray Gun; Preparation For Starting Up - WAGNER GM 5000EAC Operating Manual

Electrostatic aircoat spray gun for manual operation with fl at or round jet nozzles
Hide thumbs Also See for GM 5000EAC:
Table of Contents

Advertisement

EDITION 03/2012
OPERATING MANUAL
5.3

START-UP

5.3.1

GENERAL RULES FOR MAKING ADJUSTMENTS TO THE SPRAY GUN

➞ Observe safety instructions in Chapter 2.
High voltage field!
Danger to life from malfunctioning heart pacemakers
Ensure that persons with heart pacemakers:
SIHI_0049_GB
Unintentional putting into operation!
Risk of injury
Before all work on the unit, in the event of work interruptions and
functional faults:
SIHI_0065_GB
5.3.2

PREPARATION FOR STARTING UP

The following points should be noted before commissioning:
➞ For earthing see paragraph 5.1.5; make sure that all other conductive parts within the
work area are earthed.
➞ Connect the material hose to spray gun and material pump..
➞ Check that all material-conveying connections are correctly connected.
➞ Connect air hose to spray gun and to oil-free, dry air, approx. 0.25 MPa; 2.5 bar; 36 psi.
Compressed air quality class 3.5.2 according to ISO 8573.1.
➞ Check that all air supply connections are connected properly.
➞ Connect the electric cable to the spray gun and to the VM 5000 or VM 500 control
unit.
➞ Visually check the permissible pressures for all the system components.
PART NUMBER DOC 2319150
Do not work with the electrostatic spray gun.
Remain outside the area of the electrostatic spray gun/work -
piece.
Switch off the energy/compressed air supply.
Relieve the pressure from the spray gun and unit.
Secure the spray gun against actuation.
By functional faults: Identify and correct the problem, proceed
as described in chap „Trouble shooting".
DANGER
WARNING
GM
5000EAC.
28

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gm 5000eac fGm 5000eac r2309871

Table of Contents