Engine Data 12V4000M93L, Heat Exchanger Installed, Epa Stage - MTU 12V4000M93 series Operating Instructions Manual

Table of Contents

Advertisement

3.3 ENGINE DATA 12V4000M93L, heat exchanger installed, EPA
stage 2
Explanation:
DL Ref. value: Continuous power
BL Ref. value: Fuel stop power
A Design value
G Guaranteed value
R Guideline value
L Limit value, up to which the engine can be operated without changes (e.g. of power setting)
N Not yet defined value
- Not applicable
X Applicable
REFERENCE CONDITIONS
Engine model
Application group
Intake air temperature
Raw water inlet temperature
Barometric pressure
Site altitude above sea level
POWER-RELATED DATA (power ratings are net brake power as per ISO 3046)
Number of cylinders
Rated engine speed
Fuel stop power ISO 3046
GENERAL CONDITIONS (for maximum power)
Number of cylinders
Intake depression (new filter)
Intake depression, max.
MODEL RELATED DATA (basic design)
Number of cylinders
Cylinder arrangement: V angle
Bore
Stroke
Displacement per cylinder
Displacement, total
Number of inlet valves per cylinder
Number of exhaust valves per cylinder
A
A
A
L
MS150047/05E 2018-08 | Technical Data | 67
12V4000
M93L
1DS
°C
25
°C
25
mbar
1000
m
100
12
rpm
2100
kW
2580
12
mbar
15
mbar
30
12
Degrees
90
mm
170
mm
190
Liters
4.31
Liters
51.72
2
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

16v4000m93 series16v4000m93l12v4000m9312v4000m93l16v4000m93