MTU 12V4000M93 series Operating Instructions Manual page 146

Table of Contents

Advertisement

576 – AL ESCM Override
Cause
Violation of corrected MCR or
DBR/MCR curve. Engine overload!
577 – SD T-Lube Oil Pan
Cause
Temperature sensor in oil pan
defective; Short circuit or wire
break
582 – AL Emergency Stop Failed
Cause
This alarm occurs if the engine
fails to come to a standstill within
a specified (by parametrization)
period of time after the
emergency stop signal was
output.
588 – SD P-Oil Refill Pump
Cause
Pressure sensor faulty; Short
circuit or wire break
596 – AL Develop PR Set
Cause
The parameter set used is a test
parameter set.
600 – SD T-Exhaust A+B
Cause
SD T-Exhaust A and T-Exhaust B
144 | Troubleshooting | MS150047/05E 2018-08
ZKP-Number: 1.1075.083
Corrective action
u Reduce power.
ZKP-Number: 1.0137.900
Corrective action
u Check sensor and cabling, replace as necessary.
ZKP-Number: 1.1005.006
Corrective action
u The delay between the emergency stop signal and this alarm signal
is set in parameter 1.1005.4.
ZKP-Number: 1.0159.910
Corrective action
u Check sensor and cabling, replace as necessary.
ZKP-Number: 1.8004.645
Corrective action
u The alarm remains active until a series-production parameter set
was installed.
ZKP-Number: 1.8004.646
Corrective action
u Check sensor and cabling, replace as necessary.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

16v4000m93 series16v4000m93l12v4000m9312v4000m93l16v4000m93

Table of Contents