RAW WATER CIRCUIT (open circuit)
Number of cylinders
Raw water pump: Inlet pressure, min.
Raw water pump: Inlet pressure , max.
Pressure loss in external raw water system, max.
LUBE OIL SYSTEM
Number of cylinders
Lube oil operating temperature before engine, from
Lube oil operating temperature before engine, to
Lube oil operating pressure before engine, from
Lube oil operating pressure before engine, to
Lube oil operating pressure, low idle (meas. point: before engine)
FUEL SYSTEM
Number of cylinders
Fuel pressure at engine supply connection, min. (when engine is starting)
Fuel pressure at engine supply connection, min. (when engine is running)
Fuel pressure at engine supply connection, max. (when engine is starting)
Fuel supply flow, max.
GENERAL OPERATING DATA
Number of cylinders
Firing speed, from
Firing speed, to
STARTING (electric)
Number of cylinders
Starter, rated voltage (standard design)
STARTING (with compressed air/hydraulic starter)
Number of cylinders
Starting-air pressure before starter motor, min.
Starting-air pressure before starter motor, max.
INCLINATIONS, STANDARD OIL SYSTEM (reference: waterline)
Number of cylinders
Longitudinal inclination, continuous max., driving end down (option: max. oper-
ating inclinations)
Longitudinal inclination temporary max. drive side down (design: max. operat-
ing inclinations)
L
L
L
R
R
R
R
R
L
L
L
R
R
R
R
R
R
L
L
MS150047/05E 2018-08 | Technical Data | 65
12
bar
-0.2
bar
0.5
bar
0.7
12
°C
72*
°C
80*
bar
6
bar
8
bar
2.0
12
bar
-0.1
bar
-0.3
bar
1.5
liter/min
30
12
rpm
80
rpm
120
12
V=
24
12
bar
8
bar
10
12
Degrees
15
Degrees
22.5