Engines with remote raw water cooler and vertical air intake
1 Coolant outlet to remote
cooling system
2 Coolant inlet from remote
cooling system
3 Engine management and
monitoring
4 Oil cooler
5 Centrifugal oil filter
6 Crankcase breather
7 Dry-type air filter
8 Exhaust manifold
9 Recirculation line
48 | General Information | MS15035/00E 2018-08
10 Exhaust turbocharger
11 Exhaust outlet
12 Air pipe to charge-air cooler
13 Charge-air cooler
14 Engine mounting
15 Charge-air line
16 Oil pan
17 Oil filler neck
18 Crankcase
19 Cylinder head
20 Fuel filter
21 Oil filter
22 HP fuel pump
23 Battery-charging generator
24 Bilge pump (option)
KGS Free end