MTU 16V4000M*3 series Operating Instructions Manual page 127

Hide thumbs Also See for 16V4000M*3 series:
Table of Contents

Advertisement

230 – SD Crankshaft Speed
Cause
Crankshaft sensor faulty; Short
circuit or wire break
231 – SD Camshaft Speed
Cause
Camshaft sensor faulty; Short
circuit or wire break
232 – SD Charger 1 Speed
Cause
Speed sensor of primary
turbocharger faulty; Short circuit
or wire break
233 – SD Charger 2 Speed
Cause
Speed sensor of secondary
turbocharger faulty; Short circuit
or wire break
239 – SD P-Diff Fuel
Cause
Fuel differential pressure sensor
faulty; occurs only in combination
with alarm "SD P-Fuel before
Filter" or "SD P-Fuel after Filter".
240 – SD P-Fuel
Cause
Fuel pressure sensor faulty; Short
circuit or wire break
ZKP-Number: 1.8004.498
Corrective action
1. Check sensor and cabling (B13), replace as necessary.
2. Error cleared after restarting the engine.
ZKP-Number: 1.8004.499
Corrective action
1. Check sensor and cabling (B1), replace as necessary.
2. Error cleared after restarting the engine.
ZKP-Number: 1.3011.128
Corrective action
1. Check sensor and cabling (B44.1), replace as necessary.
2. Error cleared after restarting the engine.
ZKP-Number: 1.3011.129
Corrective action
1. Check sensor and cabling (B44.2), replace as necessary.
2. Error cleared after restarting the engine.
ZKP-Number: 1.8004.598
Corrective action
u Note further fault messages. Pressure sensor before or after filter
is faulty.
ZKP-Number: 1.8004.565
Corrective action
1. Check sensor and cabling (B34), replace as necessary.
2. Error cleared after restarting the engine.
MS15035/00E 2018-08 | Troubleshooting | 125

Hide quick links:

Advertisement

Table of Contents
loading