508 – AL Wrong POM-ID
Cause
POM transmits an unexpected ID
number. If alarm occurs in
combination with alarm 504, the
resistor in the POM cabling is
missing.
519 – Oillevel Calibration Error
Cause
Error when writing the calibration
value into the Flash or SD memory
of the level sensor; associated PV:
AL Group 6 Mot Bit 11
525 – SD P-Lube Oil (R2)
Cause
Redundant lube oil pressure
sensor faulty; Short circuit or wire
break
526 – SD T-Coolant (R2)
Cause
Redundant coolant temperature
sensor faulty; Short circuit or wire
break
527 – TD EngineSpd. Sensor Deviation
Cause
Maximum deviation of speed
sensors
528 – SD Engine Speed 3rd Sensor
Cause
Redundant crankshaft sensor
faulty; Short circuit or wire break
ZKP-Number: 1.4500.908
Corrective action
u Check POM wiring harness.
ZKP-Number: 1.0158.921
Corrective action
1. Check sensor and cabling, replace as necessary.
2. Contact Service.
ZKP-Number: 1.8004.638
Corrective action
u Check sensor and cabling, replace as necessary.
ZKP-Number: 1.8004.639
Corrective action
u Check sensor and cabling, replace as necessary.
ZKP-Number: 1.0480.093
Corrective action
1. Check cabling of speed sensors. Observe additional messages.
2. Contact Service.
ZKP-Number: 1.2500.102
Corrective action
u Check sensor and cabling, replace as necessary.
MS15035/00E 2018-08 | Troubleshooting | 143