309 – AL Timing Cylinder A9
Cause
Time-of-flight measuring fault of
injector in cylinder A9: Time-of
flight measured value extremely
low or extremely high.
310 – AL Timing Cylinder A10
Cause
Time-of-flight measuring fault of
injector in cylinder A10: Time-of
flight measured value extremely
low or extremely high.
311 – AL Timing Cylinder B1
Cause
Time-of-flight measuring fault of
injector B1: Time-of flight
measured value extremely low or
extremely high.
312 – AL Timing Cylinder B2
Cause
Time-of-flight measuring fault of
injector B2: Time-of flight
measured value extremely low or
extremely high.
313 – AL Timing Cylinder B3
Cause
Time-of-flight measuring fault of
injector B3: Time-of-flight
measurement value is extremely
small or extremely large.
128 | Troubleshooting | MS15035/00E 2018-08
ZKP-Number: 1.8004.508
Corrective action
u If alarm occurs frequently, replace solenoid valve of injector
ZKP-Number: 1.8004.509
Corrective action
u If alarm occurs frequently, replace solenoid valve of injector
ZKP-Number: 1.8004.510
Corrective action
u If alarm occurs frequently, replace solenoid valve of injector
ZKP-Number: 1.8004.511
Corrective action
u If alarm occurs frequently, replace solenoid valve of injector
ZKP-Number: 1.8004.512
Corrective action
u If alarm occurs frequently, replace solenoid valve of injector

Hide quick links: