1. Using a 4 mm internal hex wrench remove screws (M36).
2. Remove the housing cover (M10). Remove gasket (M12).
3. Remove spring (M16).
4. Remove housing (M1HP) with the shuttle valve assembly.
5. Remove the pilot piston (M14). Remove and discard O-ring (M24).
6. Remove pin (M18) from the multifunction block.
7. Use screw (M36) as a threaded puller to remove plug (M28). Remove O-ring (M30).
8. Remove shuttle spool (M26).
9. Remove plug (M32). Remove O-ring (M30).