Pcor; Optional Pcor Housing; Disassembly; Inspection - Danfoss 51 Series Service Manual

Hydraulic proportional controls
Hide thumbs Also See for 51 Series:
Table of Contents

Advertisement

Service Manual

PCOR

Optional PCOR Housing

14
Series 51 Hydraulic Proportional Controls Service Manual

Disassembly

1. Remove plugs (N27). Remove and discard O-rings (N27A).
2. Using a 1 inch wrench, remove plug (N23). Remove and discard O-ring (N23A).
3. Remove locknut (N14).
4. Remove adjustment plug (Z00). Remove and discard O-ring (N16J).
5. Remove spring (N18).
6. Remove spool and spring guide assembly (N20).
7. Remove screws (N29).
8. Remove and discard O-rings (N24P, N82).
9. If present, remove orifices (U6, U7).
PCOR
U7
U6
N27
N23
Legend
Item
N27
N23
U6, U7
N29
N14

Inspection

Clean and inspect components for damage or foreign material. Replace damaged parts.

Assembly

1. If previously removed, use a 3mm internal hex wrench to install orifices (U6, U7). Torque to 6 N•m [4
lbf•ft].
2. Using petroleum jelly to retain them, install new interface O-rings (N24P, N82).
3. Position PCOR on multiblock. Install screws (N29). Torque using a 5 mm internal hex wrench to 16
N•m [12 lbf•ft].
11009446 • Rev BA • July 2014
N82
N20
N24P
N8 7
N18
N27
Wrench size
1/8 inch internal hex
1 inch
3 mm internal hex
5 mm internal hex
1-5/16 inch
N14
N16J
Z00
N29
P106 384E
Torque
7 Nm [4 lbf•ft]
40 Nm [30 lbf•ft]
6 Nm [4 lbf•ft]
16 Nm [12 lbf•ft]
N/A