Sample Of Serial Number / Safety Label - Quadra-Fire SANTAFEI-MBK Owner's Manual

Pellet insert appliance
Hide thumbs Also See for SANTAFEI-MBK:
Table of Contents

Advertisement

Santa Fe Pellet Insert
NOTE: Clearances may only be reduced by means approved
A. Sample of Serial Number / Safety Label
LOCATION: On chain behind right access panel & Behind left access panel
SANTA FE PELLET INSERT
SERIAL NO.
/ NUMÉRO DE SÉRIE
US015
2017 2018 2019
JAN FEB MAR APR MAY JUNE
JULY AUG SEPT OCT NOV DEC
Report / Rapport: 061-S-77c-6.2
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with 2015 particulate emission standards
at 1.8 g/hr EPA Method 28 and 5G. Not approved for sale
Input Rating: 38,700 Btu's/hr
after May 15, 2020.
THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION.
CONSULT THE OWNER'S MANUAL FOR FURTHER INFORMATION. IT IS AGAINST FEDERAL
REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH THE
OPERATING INSTRUCTIONS IN THE OWNER'S MANUAL.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE
Made in China/ Fait Aux Chine
SAMPLE:
SERIAL NUMBER LABEL
LOCATION:
Behind left access panel.
2
and Welcome to the Quadra-Fire Family
by the regulatory authority having jurisdiction
7019-222H
SAMPLE: CLEARANCE TO COMBUSTIBLES LABEL
O-T L
Tested and
Portland
Listed by
Oregon USA
US
C
OMNI-Test Laboratories, Inc.
Report No.
#061-S-77d-6.2
Electrical Rating: 115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 AMPS.
Listed Solid Fuel Room Heater/Pellet Type Insert. Also suitable for Mobile Home Installation. This appliance has been tested
and listed for use in Manufactured Homes in accordance with OAR 814-23-9000 through 814-23-909.
Tested to: ASTM E-1509-2004, ULC S628-93, ULC /ORD-C1482-M1990 Room Heating Pellet Burning Type, (UM) 84-HUD FOR
USE ONLY WITH PELLETIZED WOOD OR SHELLED FIELD CORN FUEL. Do not use any other type of fuel. OMNI-Test Laboratories,
Inc. has determined that this appliance complies with Canadian Standards Association (CSA) B415.1 and Title 40 of the
U.S. Code of Federal Regulations, Part 60, SubPart AAA.OMNI-Test Laboratories Accrediations: The Standards
Council of Canada, the American National Standards Institute, and the U.S. Environmental Protection Agency.
Route power cord away from unit. Do not route cord under or in front of appliance.
DANGER: Risk of electrical shock. Disconnect power supply before servicing. Replace glass only with 5mm ceramic available
from your dealer.
To start, set thermostat above room temperature, the appliance will light automatically. To shutdown, set thermostat to below room
temperature. For further instruction refer to owner's manual.
KEEP VIEWING AND ASH REMOVAL DOORS TIGHTLY CLOSED DURING OPERATION.
Install and use only in accordance with manufacturer's installation and operating instructions. CONTACT LOCAL BUILDING
OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.
WARNING - FOR MOBILE HOMES: Do not install appliance in a sleeping room. An outside combustion air inlet must be
provided. The structural integrity of the mobile home floor, ceiling and walls must be maintained.
Refer to manufacturer's instructions and local codes for precautions required for passing chimney through a combustible wall
or ceiling. Inspect and clean vent system frequently in accordance with manufacturer's instructions.
Do Not Connect This Unit to a Chimney Serving Another Appliance.
Use a 3" or 4" diameter type "L" or "PL" venting system.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
A
B
C
0 in. Clearance To Exposed Section And Face Trim
Max. Mantel Depth: 12 in. (305mm)
MANTEL
B
C
A
E
F
DO NOT REMOVE THIS LABEL
LOCATION: On chain behind right access panel
7019-229G
!
English
SAFETY LABEL
R
Santa Fe Pellet Insert-MBK
352 Mountain House Road, Halifax, PA 17032
Input Rating: 30,000 BTU/HR.
PREVENT HOUSE FIRES
AS A BUILT-IN UNIT
C
D
A Top of Hopper
B
B Side of Hopper
C Back of Hopper
D Vent Pipe to Combustible Top/Rear Vent 3.0 in. 76mm
Masonry or Zero Clearance
A Insert side to combustible side wall
Face Trim
B Insert top to mantel
C Insert top to max. 2.25 in. to top face trim
D Insert side to max. 2.25 in. to side face trim
D
E Hearth extension to from door opening - front 6 in .
F Hearth extension from side of door opening
*When constructing floor protection for your pellet appliance, any
parts or materials used, must be non-combustible.
www.quadrafire.com
Top Vent
2.0 in. 51mm
Rear Vent
2.5 in. 64mm
Top/Rear Vent 2.0 in. 51mm
Top/Rear Vent 2.5 in. 64mm
16 in.
406mm
12 in.
305mm
4.75 in.
121mm
10 in.
254mm
152mm
6 in.
152mm
7019-223F
August 3, 2018
UNLESS OTH