Sample Of Serial Number / Safety Label - Quadra-Fire 21M-ACC Owner's Manual

2100 millennium wood appliance automatic combustion control (acc)
Hide thumbs Also See for 21M-ACC:
Table of Contents

Advertisement

2100 Millennium
NOTE: Clearances may only be reduced by means approved
A. Sample of Serial Number / Safety Label
LOCATION: Back of appliance
CAUTION
ATTENTION:
APPAREIL DE CHAUFFAGE DE PIÈCE, DE TYPE DE
COMBUSTIBLE SOLIDE, POUR USAGE DANS LES
LISTED ROOM HEATER, SOLID FUEL TYPE.
MAISONS MOBILES. (UM) 84-64 HUD. "Pour Usage
ALSO FOR USE IN MOBILE HOMES. (UM) 84 HUD .
Avec Bois Solide Seulement"
"For Use with Solid Wood Fuel Only"
PRÉVENTION DES FEUX DE MAISON
PREVENT HOUSE FIRES
Install
and
use
only
in
accordance
with
Installez et utilisez en accord avec les instructions
manufacturer's
installation
and
operating
d'installation et d'opération du fabricant. Contactez le bureau
instructions. Contact local building or fire officials
de la construction ou le bureau des incendies au sujet des
about restrictions and installation inspections in
restrictions et des inspections d'installation dans votre
your area. Do not obstruct the space beneath
voisinage. Ne pas obstruez l'espace en dessous de l'appareil.
heater.
AVIS - Pour Les Maisons Mobiles: Ne pas installer dans une
For use with leg and pedestal options intended for
chambre à coucher. Un tuyau extérieur de combustion d'air
this model, refer to owner's manual for appropriate
doit être installé et ne doit pas être obstrué lorsque l'appareil
part numbers and installation instructions.
est en usage. La structure intégrale du plancher, du plafond et
WARNING - For Mobile Homes: Do not install in
des murs de la maison mobile doit être maintenue intacte.
a sleeping room. An outside combustion air inlet
L'appareil de chauffage doit être fixé à la charpente de la
must be provided and unrestricted while unit is in
maison mobile. Les composants requis pour l'installation des
use. The structural integrity of the mobile home
maisons mobiles: Assemblage d'air extérieur, Numéro de
floor, ceiling and walls must be maintained. The
Pièce OAK-ACC.
stove needs to be properly grounded to the frame
Référez vous aux instructions du fabricant et des codes
of the mobile home.
Components required for
locaux pour les précautions requises pour passer une
mobile home installation:
Outside Air Kit, Part
cheminée à travers un mur ou un plafond combustibles, et les
Number OAK-ACC.
compensations maximums.
Refer to manufacturer's instructions and local
Inspectez et nettoyez la cheminée fréquemment. Sous
codes for precautions required for passing
certaines conditions, il se peut que la créosote s'accumule
chimney through a combustible wall or ceiling and
rapidement.
maximum offsets.
Ne pas connecter cet appareil à une cheminée servant un
Inspect and clean chimney frequently - Under
autre appareil.
Certain Conditions of Use, Creosote Buildup May
Composants Optionnels: Ventilateur Optionnel, Pièce
Occur Rapidly.
BK-ACC.
Do not connect this unit to a chimney serving
Puissance Électrique: 115 VAC, 1.2 Amps, 60 Hz.
another appliance.
Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil
Optional Blower, Part BK-ACC.
électrique au dessus ou en dessous de l'appareil.
Electrical Rating: 115 VAC, 1.2 Amps, 60 Hz.
DANGER: Il y a risque de décharge électrique. Déconnectez
Route power cord away from unit. Do not route
le fil électrique de la prise de contact avant le service.
cord under or in front of appliance.
Remplacez la vitre seulement avec une vitre céramique de 5
DANGER: Risk of electrical shock. Disconnect
mm disponible chez votre fournisseur.
power supply before servicing.
N'élevez pas le feu. Bâtissez le feu de bois directement sur
Replace glass only with 5mm ceramic available
l'âtre.
from your dealer.
Ne pas surchauffer. Si l'appareil de chauffage ou le tuyau de
Do not use grate or elevate fire. Build wood fire
cheminée rougissent, vous surchauffez.
directly on hearth.
Opérez l'appareil seulement lorsque la porte de chargement
Do not overfire - if heater or chimney connector
est fermée. Ouvrez la porte seulement lorsque vous devez
glows, you are overfiring.
ajouter des combustibles dans le feu.
Operate only with the fuel loading door closed.
Open only to add fuel to the fire.
FLOOR PROTECTION
PROTECTION DU PLANCHER
:
Floor protector must be a 3/8 (9.5mm) inch min.
Le protecteur de plancher doit être d'un minimum de 3/8 inch
(9.5mm) d'épaisseur, de matériel incombustible ou
thickness, non-combustible material or equivalent,
équivalent, s'étendant du dessous de l'appareil de chauffage
extending beneath heater and to front/sides/rear as
à l'avant, aux cotés et à l'arrière comme indiqué sur le
indicated on the diagram below. Exception:
diagramme
Non-combustible floor protections must extend
incombustibles du plancher doivent s'étendre en dessous du
beneath the flue pipe when installed with horizontal
conduit de cheminée lorsqu'installées avec une ventilation à
l'horizontale et s'étendre de 2 inches (51mm) de chaque
venting and extend 2 inches (51mm) beyond each
côté.
side.
203mm
(8 in.)
5-3/4 in.
2-1/4 in."
39 in.
Fuel loading door
minimum
8 in.
16" from glass
USA
29-5/8 in.
minimum
Manufactured by:
Fabriqué par:
352 Moutain House Road, Halifax, PA 17032
www.quadrafire.com
ECO #
DATE
2
by the regulatory authority having jurisdiction
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. KEEP
:
FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS
CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES
BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L'ESPACE DÉSIGNÉ DE L'APPAREIL. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS.
Tested and
O-T L
Listed by
Oregon USA
C
US
OMNI-Test Laboratories, Inc.
Report
/ Rapport
0061WS070S
SINGLE WALL: Six inch (6 inches) (152mm) diameter, minimum 24 MSG black or
blued steel connector pipe, with a listed factory-built UL103HT* Class "A" chimney,
suitable for use with solid fuels, or a masonry chimney, and the referenced clearances.
DOUBLE WALL: Six inch (6 inches) (152mm) diameter, listed double wall air
insulated connector pipe with listed factory-built UL103HT* Class "A" chimney, or a
masonry chimney and the referenced clearances
*In Canada must comply with Standard CAN/ULC-S629-M87 for the 650 degree
Factory-built chimneys.
MOBILE HOME: Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos DS or
Security DL double wall connector pipe. Must be equipped with a spark arrestor.
Apply double wall clearances below when installing unit.
MINIMUM CLEARANCES TO COMBUSTIBLES In Inches & (Millimeters)
NOTE: All "A" , "C" and "F" Dimensions are to inside diameter of the flue collar.
INSTALLATION: FULL VERTICAL / ENTIÈREMENT VERTICALE
SINGLE WALL PIPE
DOUBLE WALL PIPE
INSTALLATION: HORIZONTAL WITH MINIMUM 2 FT VERTICAL OFF STOVE TOP
INSTALLATION: HORIZONTALE AVEC 609mm VERTICAL MINIMUM DU HAUT DU POÊLE
SINGLE WALL PIPE
DOUBLE WALL PIPE
INSTALLATION: ALCOVE - Six inch (6 inches) (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL 103 HT listed factory-built
Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.) Maximum depth of Alcove shall be no more than 48
inches (1220mm) with a minimum height of 43 inches (1092mm) to top of unit, and the referenced clearances.
INSTALLATION: ALCÔVE - De six (6 inches) (152mm) de diamètre, le connecteur du conduit d'air isolé pour mur double avec une cheminée bâtit en usine 103HT de Classe "A", ou une
:
cheminée de briques. (Les maisons mobiles doivent être équipées d'un arrêt d'étincelle). La profondeur maximum de l'alcôve ne doit pas être de plus de 48 inches (1220mm) avec une
hauteur minimum de 43 inches (1092mm) du haut de l'appareil, et des espaces libres alloués.
DOUBLE WALL PIPE
suivant.
Exception:
Les
protections
ALCOVE SIDE VIEW /
VUE DE CÔTÉ DE L'ALCÔVE
203mm (8 in.)
203mm
(8 in
.)
G
1245mm
(49 in.)
minimum
457mm (18 in.)
CANADA
1006mm (39-5/8 in.)
minimum
Made in U.S.A. of US and
This wood heater needs periodic inspection and repair for proper operation. Consult the owner's manual for further information. It is against
federal regulations to operate this wood heater in a manner inconsistent with the operating instructions in the owner's manual.
imported parts.
2017
2018
2019
JAN
FEB
Fabriqué aux
États-Unis-d'Amérique par des
pièces d'origine américaine et
pièces importées.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE
UNLESS OTHERWISE SPECIFIED DIMS ARE INCHES[MM] & : TOLERANCES ARE: (2) PLACE DEC : ± 0.03
OUTSIDE MATERIAL.
NORMAL DIM & INSIDE MATERIAL.
BY
CONFIDENTIAL PROPERTY OF HEARTH & HOME TECHNOLOGIES INC.
ITEM
PART NUMBER
Portland
R
2100 ACC Series
TESTED TO:/ TESTÉ À:
UL 1482-11 (R2015), ULC S627-00.
VENT SPECIFICATIONS:
MUR SIMPLE: De six (6 inches) (152mm) de diamètre le connecteur de conduit de
minimum d'acier noir ou bleu de minimum de 24MSG, avec une cheminée bâtit en
usine UL103HT* de Classe "A", adéquate pour usage avec les combustions solides,
ou une cheminée de briques, avec espaces libres référés.
MUR DOUBLE: De six (6 inches) (152mm) de diamètre, le connecteur du conduit
d'air isolé pour mur double avec une cheminée bâtit en usine UL103HT* de Classe
"A, ou une cheminée de briques, avec espaces libres alloués.
*Au Canada doit conformer a CAN/ULC-S629-M87 la norme pour 650 degré C cheminée
bâtit en usine.
MAISON MOBILE: Utiliser un conduit de mur double par Dura-Vent DVL, Selkirk
Metalbestos DS ou Security DL. Doit êttre équipé d'un arrêt d'étincelle. Utiliser les
espaces libres pour mur double comme mentionné ci-bas.
ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES En Pouces &
(millimètres)
NOTE: Toutes les dimensions "A", "C", et "F" sont à partir du diamètre intérieur
de l'entrée du conduit.
A
B
C
D
E
F
15 (381)
11 (279) 21.5 (546)
13 (330)
8.5 (216)
17 (432)
8.75 (222) 5.75 (146) 20 (508)
10.5 (267)
7.5 (191)
16 (406)
14 (356) 10 (254) 20.5 (521)
12 (305)
8.5 (216)
17 (432)
9.5 (241) 5.5 (140) 21.5 (546)
13 (330)
7.5 (191)
16 (406)
9.5 (241) 5.5 (140) 21.5 (546) 13.5 (343)
N/A
N/A
43 (1092) 5 (127)
ALCOVE TOP VIEW /
VUE DU HAUT DE L'ALCÔVE
A
C
B
D
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
DEC
21 MILLENIUM
DISCOVERY I
OUTSIDE APEX
PART NAME:
DRAWN BY:
SCALE:
THIS PRINT IS CHECKED AND CONTROLLED BY THE ENGINEERING
DEPARTMENTS OF HEARTH & HOME TECHNOLOGIES INC.
7039-177C
PART NAME
Serial No. / N° de série
HF
BARCODE LABEL
SPÉCIFICATIONS DE LA VENTILATION:
G
H
BACKWALL/SIDEWALL
MUR ARRIÈRE/MUR DE CÔTÉ
56 (1422)
N/A
CONDUIT DU MUR SIMPLE
43 (1092)
N/A
CONDUIT DU MUR SIMPLE
A
B
56 (1422) 9.5 (241)
CONDUIT DU MUR SIMPLE
43 (1092)
5 (127)
CONDUIT DU MUR SIMPLE
CORNER INSTALLATION
INSTALLATION DU COIN
E
F
CONDUIT DU MUR DOUBLE
H
F
G
STOVE TO CEILING CLEARANCE
ESPACE LIBRE DU POÊLE AU PLAFOND
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with 2015 particulate emission standards at 2.1 g/hr
EPA method 28 and 5G. Not approved for sale after May 15, 2020.
(3) PLACE DEC: ± 0.005
ANGLE: ± 2°
FRACTION: ± 1/16
INSIDE APEX - DIMS ENCLOSED BY AN OVAL ARE CRITICAL DIMENSIONS
MATERIAL:
PART NUMBER:
SHEET:
QTY
Serial No.
Model
Name
Test Lab &
Report No.
C
D
E
Mfg. Date
7039-134_R11
REV:
August 13, 2018