Thermostat Battery Replacement - Quadra-Fire SANTAFEI-MBK Owner's Manual

Pellet insert appliance
Hide thumbs Also See for SANTAFEI-MBK:
Table of Contents

Advertisement

KEYPAD LOCKOUT:
There is the option to lock the front panel buttons to prevent
unauthorized tampering of your thermostat settings.
To Lock the Keypad:
1. Move TEMPERATURE switch to HEAT.
2. Move SET switch to RUN.
3. Perform a single press of each button in the following
sequence:
NEXT, NEXT, NEXT, HOLD
A padlock will appear on the display screen.
To Unlock the Keypad:
1. Move TEMPERATURE switch to HEAT.
2. Move SET switch to RUN.
3. Perform a single press of each button in the following
sequence:
NEXT, NEXT, NEXT, HOLD
A padlock will no longer be present on the display screen.
HARDWARE RESET:
The hardware reset button; labeled HW RST, is a small
round push button that is located in the middle of the circuit
board, just below the battery holder (Figure 15.1). Pressing
this button will:
Cause the LCD display screen to become fully
populated
Thermostat to perform an internal system check of its
components
If the thermostat appears to be acting in an erratic manner,
pressing the HW RST button may remedy this behavior.
The temperature programs are not erased when a
hardware reset is performed, however the clock will have to
be changed to match the current day and time.
Figure 15.1
August 3, 2018
HW
RST
SOFTWARE RESET:
Software reset is used to erase ALL temperature events,
and to return all user-adjustable software settings back to
their original factory default settings.
To Perform a Software Rest:
1. Verify the thermostat's keypad is not locked.
2. Move TEMPERATURE switch to OFF.
3. Press and hold the UP, DOWN, and NEXT buttons all
at the same time for at least 5 seconds. When the LCD
display screen will become fully populated let go of all
buttons at that point the screen will return to normal.
The clock will have to be changed to match the current day
and time.
R. Thermostat Battery Replacement
This thermostat is powered by two "AA" Alkaline batteries.
The batteries should be replaced AT LEAST once per
year to ensure reliable operation or sooner if the LO BATT
appears on the display screen. The batteries are located on
the back of the thermostat's circuit board. The front portion
of the thermostat can be removed from the back half by
using the tabs on the top edge of the thermostat housing
(Figure 15.2).
Figure 15.2
When installing new batteries, it is recommended using
only brand new "AA" size alkaline batteries. Please verify
the polarity markings shown in the battery compartment
before adding batteries to the compartment. When finished,
line up the front of the thermostat to the base, and firmly
press together to securely latch the front and back halves
together properly.
BATTERY GRAPHIC:
Anytime time the batteries are physically present in the
thermostat, there will be a visual indicator showing the
life of the battery. This will appear on the display screen
(Figures 15.3 & 15.4).
Figure 15.3 - Full
battery icon
7019-229G
Santa Fe Pellet Insert
Figure 15.4 - Low
battery icon
15

Advertisement

Table of Contents
loading