5700 STEP TOP ACC
NOTE: Clearances may only be reduced by means
approved by the regulatory authority having jurisdiction
A. Sample of Serial Number / Safety Label
LOCATION: Back of appliance
CAUTION
ATTENTION:
LISTED ROOM HEATER, SOLID FUEL TYPE.
APPAREIL DE CHAUFFAGE DE PIÈCE, DE TYPE DE
ALSO FOR USE IN MOBILE HOMES. (UM)
COMBUSTIBLE SOLIDE, POUR USAGE DANS LES
84-HUD . "For Use with Solid Wood Fuel Only"
MAISONS MOBILES. (UM) 84 HUD. "Pour Usage Avec
Bois Solide Seulement"
PREVENT HOUSE FIRES
PRÉVENTION DES FEUX DE MAISON
Install and use only in accordance with manufacturer's
Installez et utilisez en accord avec les instructions
installation and operating instructions. Contact local
d'installation et d'opération du fabricant. Contactez le
building or fire officials about restrictions and
bureau de la construction ou le bureau des incendies au
installation inspections in your area. Do not obstruct
sujet des restrictions et des inspections d'installation dans
the space beneath heater.
votre voisinage. Ne pas obstruez l'espace en dessous de
For use only with leg and pedestal options intended
l'appareil.
for this model, refer to owner's manual for appropriate
CONVIENT POUR UNE INSTALLATION MAISON MOBILE
part numbers and installation instructions.
AVIS - Pour Les Maisons Mobiles: Ne pas installer dans
SUITABLE FOR MOBILE HOME INSTALLATION
une chambre à coucher. Un tuyau extérieur de
WARNING - For Mobile Homes: Do not install in a
combustion d'air doit être installé et ne doit pas être
obstrué lorsque l'appareil est en usage. La structure
sleeping room. An outside combustion air inlet must
intégrale du plancher, du plafond et des murs de la
be provided and unrestricted while unit is in use. The
maison mobile doit être maintenue intacte. L'appareil de
structural integrity of the mobile home floor, ceiling
chauffage doit être fixé à la charpente de la maison
and walls must be maintained. The stove needs to be
mobile. Les composants requis pour l'installation des
properly grounded to the frame of the mobile home.
maisons mobiles: Assemblage d'air extérieur, Numéro de
Components required for mobile home installation:
Pièce OAK-ACC.
Outside Air Kit, Part Number OAK-ACC.
Référez vous aux instructions du fabricant et des codes
Refer to manufacturer's instructions and local codes
locaux pour les précautions requises pour passer une
for precautions required for passing chimney through
cheminée à travers un mur ou un plafond combustibles,
et les compensations maximums.
a combustible wall or ceiling and maximum offsets.
Inspectez et nettoyez la cheminée fréquemment. Sous
Inspect and clean chimney frequently - Under Certain
certaines conditions, il se peut que la créosote
Conditions of Use, Creosote Buildup May Occur
s'accumule rapidement.
Rapidly.
Ne pas connecter cet appareil à une cheminée servant un
Do not connect this unit to a chimney serving another
autre appareil.
appliance.
Composants Optionnels: Ventilateur Optionnel, Pièce
Optional Components:
Optional Blower, Part
BK-ACC.
BK-ACC.
Puissance Électrique: 115 VAC, 1.2 Amps, 60 Hz.
Electrical Rating: 115 VAC, 1.2 Amps, 60 Hz.
Éloignez le fil électrique de l'appareil. Ne pas faire passer
Route power cord away from unit. Do not route cord
le fil électrique au dessus ou en dessous de l'appareil.
DANGER: Il y a risque de décharge électrique.
under or in front of appliance.
Déconnectez le fil électrique de la prise de contact avant
DANGER: Risk of electrical shock. Disconnect power
le service.
supply before servicing.
Remplacez la vitre seulement avec une vitre céramique
Replace glass only with 5mm ceramic available from
de 5 mm disponible chez votre fournisseur.
your dealer.
N'élevez pas le feu. Bâtissez le feu de bois directement
Do not use grate or elevate fire. Build wood fire
sur l'âtre.
directly on hearth.
Ne pas surchauffer. Si l'appareil de chauffage ou le tuyau
Do not overfire - if heater or chimney connector glows,
de cheminée rougissent, vous surchauffez.
you are overfiring.
Opérez l'appareil seulement lorsque la porte de
OPERATE ONLY WITH DOORS CLOSED
chargement est fermée. Ouvrez la porte seulement
Open only to add fuel to the fire.
lorsque vous devez ajouter des combustibles dans le feu.
Ne mettez PAS le poêle en marche tant que tous les
Do NOT operate before fully assembling components.
composants n'ont pas été entièrement assemblés.
WARNING: Only used approved wood fuel listed in
owners manual. Burning any other fuel will void
ATTENTION: Seulement utilisé carburant approuvé
warranty.
indiquée dans le manuel des propriétaires. La
combustion d'autres combustibles annulera la garantie.
FLOOR PROTECTION
PROTECTION DU PLANCHER:
:
Le protecteur de plancher doit être d'un minimum de 1 inch
Floor protector must be a 1 inch min. thickness, ("k" value =
(25mm) d'épaisseur, ('k" value = .49,
.49, R value = 2.04)
non-combustible material or equivalent,
incombustible ou équivalent, s'étendant du dessous de l'appareil
extending beneath heater and to front/sides/rear as indicated
de chauffage à l'avant, aux cotés et à l'arrière comme indiqué
on the diagram below. Exception: Non-combustible floor
sur le diagramme suivant. Exception: Les protections
protections must extend beneath the flue pipe when installed
incombustibles du plancher doivent s'étendre en dessous du
with horizontal venting and extend 2 inches (51mm) beyond
conduit de cheminée lorsqu'installées avec une ventilation à
each side.
l'horizontale et s'étendre de 2 inches (51mm) de chaque côté.
45-7/8"
minimum
Fuel loading door
8"
16" from glass
USA
33-1/2"
minimum
Made in U.S.A.
Manufactured by:
imported parts.
Fabriqué par:
Fabriqué aux États-Unis-d'Amérique par
1445 N. Highway, Colville, WA 99114
des pièces d'origine américaine et pièces
www.quadrafire.com
2
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. KEEP
:
FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS
CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT
PEUT CAUSER DES BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L'ESPACE DÉSIGNÉ DE L'APPAREIL. VOIR
L'ÉTIQUETTE ET LES INSTRUCTIONS.
Tested and
O-T L
Portland
Listed by
Oregon USA
C
US
OMNI-Test Laboratories, Inc.
Report
/ Rapport
#061-S-73-6.2
VENT SPECIFICATIONS:
SINGLE WALL: Six inch (6 inches) (152mm) diameter, minimum 24 MSG black
or blued steel connector pipe, with a listed factory-built UL103HT* Class "A"
chimney, suitable for use with solid fuels, or a masonry chimney, and the
referenced clearances.
DOUBLE WALL: Six inch (6 inches) (152mm) diameter, listed double wall air
insulated connector pipe with listed factory-built UL103HT* Class "A" chimney,
or a masonry chimney and the referenced clearances
MOBILE HOME: Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos
DS or Security DL double wall connector pipe. Must be equipped with a spark
arrestor. Apply double wall clearances below when installing unit.
MIN CLEARANCES TO COMBUSTIBLE MATERIALS: Inches & (Millimeters)
NOTE: All "A" , "C" and "F" Dimensions are to inside diameter of flue collar.
INSTALLATION: FULL VERTICAL INSTALLATION: ENTIÈREMENT VERTICALE
12.5 (318) 10.5 (267) 25.5 (648) 15 (381) 2 (51) 12 (305) 45 (1143) N/A
SINGLE WALL PIPE
DOUBLE WALL PIPE
INSTALLATION: HORIZONTAL WITH MINIMUM 2 FT VERTICAL OFF STOVE TOP
INSTALLATION: HORIZONTALE AVEC 609mm VERTICAL MINIMUM DU HAUT DU POÊLE
SINGLE WALL PIPE
DOUBLE WALL PIPE
o
INSTALLATION: 90
ELBOW OFF TOP OF STOVE THROUGH BACKWALL
o
INSTALLATION: 90
DU COURBURE AU DESSUS DE HAUT DU POÊLE A TRAVERS LE MUR ARRIERE
SINGLE WALL PIPE
DOUBLE WALL PIPE
R value = 2.04)
de matériel
INSTALLATION: ALCOVE - Six inch (6 inches) (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL103 HT** listed factory-built
Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.) Maximum depth of Alcove shall be no more than 48
inches (1219mm) and the referenced alcove clearances.
INSTALLATION: ALCÔVE - Six pouces (6 pouces) (152mm) de diamètre listé air isolé tuyau de raccordement à double paroi avec UL103 HT ** cotée Classe
usine construite "A" cheminée ou une cheminée de maçonnerie. (Mobile Home doit être équipé d' un pare-étincelles.) Profondeur maximale de Alcove ne doit
pas être plus de 48 pouces (1219mm) et les dégagements en alcôve référencés.
203mm (8")
(**In Canada must comply with Standard CAN/ULC-S629-M87 for the 650
(**Au Canada doit conformer a CAN/ULC-S629-M87 la norme pour 650
203mm
203mm
(8")
(8")
1394mm
10.5 (268) 8.5 (216) 25.5 (648) 15 (381) N/A
(54-7/8")
DOUBLE WALL PIPE
minimum
*
457mm (18")
SEE PIPE MANUFACTURERS CLEARANCES - NOT TESTED
CANADA
1092mm (43")min
of US and
2016 2017 2018 Jan. Feb. Mar. Apr. May June July Aug. Sept. Oct. Nov. Dec.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE
importées.
R
5700 Step Top ACC
TESTED
TO:/ TESTÉ À:
UL 1482-11 (R2015), ULC S627-00
MUR SIMPLE: De six (6 inches) (152mm) de diamètre le connecteur de conduit de
minimum d'acier noir ou bleu de minimum de 24MSG, avec une cheminée bâtit en usine
UL103HT* de Classe "A", adéquate pour usage avec les combustions solides, ou une
cheminée de briques, avec espaces libres référés.
MUR DOUBLE: De six (6 inches) (152mm) de diamètre, le connecteur du conduit d'air
isolé pour mur double avec une cheminée bâtit en usine UL103HT* de Classe "A:, ou
une cheminée de briques, avec espaces libres alloués.
MAISON MOBILE:
Metalbestos DS ou Security DL. Doit être équipé d'un arrêt d'étincelle. Utiliser les
espaces libres pour mur double comme mentionné ci-bas.
ESPACES LIBRES MIN DES MATÉRIAUX COMBUSTIBLES:
NOTE: Toutes les dimensions "A", "C", et "F" sont à partir du diamètre intérieur
de l'entrée du conduit.
A
B
C
D
E
F
G
9.5 (241) 7.5 (191) 25.5 (648) 15 (381) 2 (51) 12 (305) 45 (1143) N/A
9.5 (241) 7.5 (191) 25.5 (648) 15 (381)
*
*
45 (1143) 18 (457) *
9.5 (241) 7.5 (191) 25.5 (648) 15 (381)
*
*
45 (1143) 13 (330)
9.5 (241) 7.5 (191) 25.5 (648) 15 (381) 2 (51) 12 (305) 45 (1143) 18 (457)*
9.5 (241) 7.5 (191) 25.5 (648) 15 (381) 2 (51) 12 (305) 45 (1143) 13 (330)
o
C Factory-built chimney.)
o
C cheminée bâtit en usine.)
N/A
45 (1143)
particulate emission standards at 2.3 G/HR EPA Methods 28 and 5G. Not approved for
proper operation. Consult the owner's manual for further information. It is against federal
7038-207G
SERIAL NO.
/ NUMÉRO DE SÉRIE
CV009
SPÉCIFICATIONS DE LA VENTILATION:
Utiliser un conduit de mur double par Dura-Vent DVL, Selkirk
En Pouces & (millimètres)
BACKWALL/SIDE
A
B
WALL/
H
MUR
ARRIÈRE/MUR
CONDUIT DU MUR SIMPLE
DE CÔTÉ
CONDUIT DU MUR DOUBLE
CORNER
E
F
INSTALLATION/
INSTALLATION
DU COIN
CONDUIT DU MUR SIMPLE
CONDUIT DU MUR DOUBLE
G
ALCOVE SIDE
VIEW /
VUE DE CÔTÉ
DE L'ALCÔVE
CONDUIT DU MUR SIMPLE
CONDUIT DU MUR DOUBLE
ALCOVE TOP
VIEW /
VUE DU HAUT DE
L'ALCÔVE
90 OFF TOP UP & OUT
CEILING CLEARANCE/
G
ESPACE LIBRE DU
DESSUS DE
L'APPAREIL AU
PLAFOND AVEC 90 DE
COURBURE
*
CONDUIT DU MUR DOUBLE
STOVE TO CEILING CLEARANCE/
ESPACE LIBRE DU POÊLE AU
PLAFOND
U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2015
sale after May 15, 2020. This wood heater needs periodic inspection and repair for
regulations to operate this wood heater in a manner inconsistent with the operating
instructions in the owner's manual.
Serial No.
Model
Name
C
Test Lab &
D
Report No.
E
F
A
B
C
D
H
Mfg. Date
7038-162H
September 28, 2016

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents