Quadra-Fire SANTAFEI-MBK Installation Manual

Santa fe pellet insert stove
Hide thumbs Also See for SANTAFEI-MBK:

Advertisement

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
SANTA FE PELLET INSERT STOVE
Model(s):
SANTAFEI-MBK
CAUTION
Tested and approved for wood pellets and corn pellets.
Burning of any other type of fuel voids your warranty.
CAUTION
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and na-
tional codes and regulations.
• Consult local building, fi re offi cials or authorities having juris-
diction about restrictions, installation inspection, and permits.
1
Installation Manual
Installation & Appliance Set-Up
NOTICE: DO NOT DISCARD THIS MANUAL
Tested and
Portland
O-T L
Listed by
Oregon USA
C
US
OMNI-Test Laboratories, Inc.
If the information in these instruc-
tions is not followed exactly, a
fi re could result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not overfi re - If heater or chimney con-
nector glows, you are overfi ring. Overfi ring
will void your warranty.
• Comply with all minimum clearances to
combustibles as specifi ed. Failure to
comply may cause house fi re.
Hot glass will cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
fi replace.
Alert children and adults to hazards of high temperatures
High temperatures may ignite clothing or other
fl ammable materials.
Keep clothing, furniture, draperies and other fl ammable
materials away.
To obtain a French translation of this manual, please contact
your dealer or visit www.quadrafi re.com
Pour obtenir une traduction française de ce manuel, s'il vous
plaît contacter votre revendeur ou visitez www.quadrafi re.com
7019-230C
WARNING
WARNING
HOT SURFACES!
Glass and other surfaces are hot
during operation AND cool down.
NOTE
May 18, 2015

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire SANTAFEI-MBK

  • Page 1 SANTA FE PELLET INSERT STOVE fi re could result causing property damage, personal injury, or death. Model(s): SANTAFEI-MBK • Do not store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2: Table Of Contents

    Santa Fe Pellet Insert Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. •...
  • Page 3: Important Safety Information

    (UM) 84-HUD B. BTU & Effi ciency Specifi cations Fire Risk. The Quadra-Fire Santa Fe Pellet Insert meets the U.S. Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, Environmental Protection Agency’s emission limits for pellet the following actions: inserts sold after May 15, 2015.
  • Page 4: Getting Started

    Santa Fe Pellet Insert Install Guide Getting Started A. Design, Installation & Location Considerations Since pellet exhaust can contain ash, soot or sparks, you must consider the location of: 1. Appliance Location • Windows NOTICE: Check building codes prior to installation. •...
  • Page 5: Thermostat Wall Control Location

    Santa Fe Pellet Insert B. Thermostat Wall Control Location WARNING The thermostat wall control’s location will have some affect on the appliance’s operation. Fire Risk. • Maximum wire length from appliance is 100 feet (30.48m) Damaged parts could impair safe operation. Do continuous unspliced wire.
  • Page 6: Install Checklist

    Installer: Dealer/ Distributor Phone #: Serial #: Model (circle one): SANTAFEI-MBK WARNING! Risk of Fire or Explosion! Failure to install fi replace according to these instructions can lead to a fi re or explosion. Appliance Install IF NO, WHY? Verifi ed clearances to combustibles. (Pg. 8) Fireplace is leveled and liner is secured to appliance.
  • Page 7: Dimensions And Clearances

    Santa Fe Pellet Insert Dimensions and Clearances A. Appliance Dimensions 28-7/8” (733mm) 23-5/8” (600mm) 8” (203mm) 25-3/8” 645mm) 23” 584mm) 12-3/4” 8-5/8” 21-1/2” 324mm) 219mm) (546mm) Figure 7.2 -Side View Figure 7.1 - Top View Figure 7.3- Front View Panel Standard 40 inches (1016mm) 30 inches (762mm)
  • Page 8: B. Clearance To Combustibles, Ul And Ulc

    Santa Fe Pellet Insert B. Clearance To Combustibles, UL and ULC AS A BUILT-IN 0 in. Clearance To Exposed Section And Face Trim Figure 8.1 Inches Millimeters Top of Hopper Top Vent Rear Vent Side of Hopper Top or Rear Vent Back of Hopper Top or Rear Vent Vent Pipe to Combustible...
  • Page 9: Masonry And Zero Clearance Fireplaces

    Santa Fe Pellet Insert C. Masonry and Zero Clearance Fireplaces NOTE It is necessary to permanently seal any opening between Maximum Mantel Depth: 12 inches (305mm) the masonry of the fi replace and the facing masonry. Face Mantel Trim E. Hearth Extension If employing a hearth extension, any parts or materials used in construction must be non-combustible.
  • Page 10: Installation Into A Factory-Built Fireplace

    Santa Fe Pellet Insert G. Installation into a Factory-Built Fireplace The following is only one example as there are many differ- ent models of factory-built fi replaces. The following modifi cations are permissible: NOTE: This example is for reference only. Any modifi ca- •...
  • Page 11: Installation Into A Masonry Fireplace

    Santa Fe Pellet Insert I. Prefabricated Metal Chimney Example Removal of Factory-Built Fireplace Cont. The chimney can be new or existing, masonry or prefabricated and must meet the following minimum requirements: • Must be minimum 6 inch (152mm) inside diameter of Keep sharp edge of high temperature chimney listed to UL 103 HT (2100 metal floor away from...
  • Page 12: Vent Information

    Santa Fe Pellet Insert Vent Information A. Venting Termination Minimum Requirements Electrical Service Inside Corner FIXED FIXED OPEN CLOSED CLOSED OPEN J or K Figure 11.1 Termination Cap Air Supply Inlet Restricted Area Gas Meter All minimum clearances are listed with an Outside Air Kit (OAK) installed, unless otherwise noted in table below. 12 in.
  • Page 13: Avoiding Smoke And Odors

    Santa Fe Pellet Insert B. Avoiding Smoke and Odors Vent Confi gurations To reduce probability of reverse drafting during shut-down Negative Pressure, Shut-Down and Electrical Power conditions Hearth & Home Technologies strongly recom- Failure mends: To reduce the probability of back-drafting or burn-back in •...
  • Page 14: Negative Pressure

    Avoid installing the appliance near doors, walkways or (76-152mm) Top Vent Offset Adapter, use Listed double wall small isolated spaces fl ue connector. A Quadra-Fire Outside Air Kit must be used with manufactured home installations. • Recessed lighting should be a “sealed can” design 3.
  • Page 15: Equivalent Feet Of Pipe

    Santa Fe Pellet Insert F. Equivalent Feet of Pipe WARNING The table below can help you calculate the equivalent feet Vent surfaces get HOT, can cause burns if of pipe which is a method used to determine pellet vent size. touched.
  • Page 16: Venting Systems

    Santa Fe Pellet Insert Venting Systems A. Full Reline With Outside Air - Horizontal CAUTION WARNING Fire Risk. Never draw outside combustion air from: Inspection of Chimney: • Wall, fl oor or ceiling cavity • Masonry chimney must be in good condition. •...
  • Page 17: Full Reline With Outside Air - Vertical

    Santa Fe Pellet Insert B. Full Reline With Outside Air - Vertical NOTE: Check clearances carefully for this type of instal- lation to ensure adequate room for outside air venting. 12” (305mm) min. above 12” (305mm) min. below CAUTION Check building codes prior to installation. •...
  • Page 18: Appliance Set-Up

    Santa Fe Pellet Insert Appliance Set-Up A. Leveling System B. Outside Air Kit Instructions The leveling bolts are located at the rear of the appliance. To Parts Included in Kit: 1 piece of 2 inch x 3 ft. fl ex hose, 2 access the bolts, remove the front access panels.
  • Page 19: Optional Grille Removal And Installation

    Santa Fe Pellet Insert C. Optional Grille Removal and Installation 6. The upper grille has 2 separate parts. Install the 3 grilles attached together fi rst. Angle the grilles downward and Included in Kit: (4) lower grilles; (3) upper grilles, (1) insert the heat exchanger cleaning rods through the holes upper grille;...
  • Page 20: Adjustable Hearth Support

    Santa Fe Pellet Insert F. Adjustable Hearth Support Size: 9”d x 45”w, 2” to 10” Height Adjustment EXPLODED VIEW OF SCISSORS Included in Kit: (1) trim top, (1) trim front, (2) trim sides, double-sided tape (already installed) Tools Needed: Phillips head screwdriver, sheet metal SCREWS ARE CIRCLED shears, measuring tape, gloves 1.
  • Page 21: Panel And Trim Set

    Santa Fe Pellet Insert G. Panel and Trim Set Open Hopper Lid for 1. Lay panel top and legs face down on protective covering Easier Placement of to prevent scratching. Panel Set Magnet 1. Attach the panel legs to the top panel using a Phillips head screwdriver.
  • Page 22: Optional Log Set Placement Instructions

    Santa Fe Pellet Insert Thermostat Installation (continued) I. Optional Log Set Placement NOTE: If the thermostat is located too close to the Two Piece Log Set Installation appliance, you may need to set the temperature Open door to expose the fi rebox. setting slightly higher to maintain the desired tem- Install the left log fi...
  • Page 23: Mobile Home Installation

    Santa Fe Pellet Insert Mobile Home Installation You must use a Quadra-Fire Outside Air Kit CAUTION for installation in a mobile home. THE STRUCTURAL INTEGRITY OF THE MOBILE HOME An outside air inlet must be provided for the combustion air and FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED must remain clear of leaves, debris, ice and/or snow.
  • Page 24: Accessory List

    Trim Plate, Outside Air Kit 412-7100 Black Nickel SP-SFI3350-NB Panel Set, Large No longer available SP-SFI3350-GD Nickel SP-SFI3350-NL Bracket, -L-, Trim 832-0840 Logo, Quadra-Fire Pkg of 10 7000-649/10 Black Nickel 7019-027 Trim, Panel Set Gold 250-4660 Black Nickel SP-SFI3040-NB Panel Set, Small...
  • Page 25 Santa Fe Pellet Insert May 18, 2015 7019-230C...
  • Page 26 Santa Fe Pellet Insert 7019-230C May 18, 2015...
  • Page 27 Santa Fe Pellet Insert May 18, 2015 7019-230C...
  • Page 28 Hearth & Home Technologies 1445 North Highway Colville, WA 99114 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer log onto www.quadrafi re.com CAUTION DO NOT DISCARD THIS MANUAL...

Table of Contents