Evaluating the safety functions according to EN ISO 13849 when using two switching devices

10.1 Evaluation of "Detect"

10.1
Evaluation of "Detect"
Result
Result
PL
PFH
D
Average probability of a dangerous failure
per hour
Determination of the PL of the EMERGENCY STOP command device
Parameter
MTTF
D
of each channel
DC
Measures against CCF
Category
Calculation of MTTF
D
Parameter
B10
B10 value EMERGENCY STOP command
device
Percentage of dangerous failures
EMERGENCY STOP command device
d
op
average operating time in days per year
h
op
average operating time in hours per day
t
cycle
average time between the start of two
consecutive cycles of the component
56
Reason
e
The values for determination are listed in the following ta-
bles.
9.06E-10
Value
Reason
High
MTTF
High
DC = 99 %
Crosswise comparison of F-DI
Fulfilled
It is assumed that the user has taken the necessary
measures.
4
System response: One single failure does not result in the
loss of the safety function. A single fault is detected.
MTTF
Value
1 * 10
5
0.2 (20 %)
365 days per year
24 hours per day
24 hours per cycle
≥ 2500 years (13,698.63 years)
D
: High, DC: High, measures against CCF: Fulfilled
D
Reason
Manufacturers data
Manufacturers data
Assumption:
The device can be actuated every
day of the year
Assumption:
there is one day between actuating
the EMERGENCY STOP
(testing the EMERGENCY STOP)
Application document for functional safety STO, SS1 (ISO 13849-1)