Table of contents
7
STO stop Category 0, several power units ..................................................................................... 39
7.1
Description .........................................................................................................................39
7.2
STO circuit example with two power units and circuit breakers............................................40
7.3
STO circuit example with two power units and power contactors .........................................41
8
SS1 stop Category 1 for several power units .................................................................................. 43
8.1
Description .........................................................................................................................43
8.2
SS1 circuit example with two power units and circuit breakers ............................................45
8.3
SS1 circuit example with two power units and circuit breakers ............................................46
9
9.1
9.2
9.3
9.3.1
Evaluation of "Respond" with one power switching device ..................................................50
9.3.1.1
Evaluation of an 3WL circuit breaker...................................................................................50
9.3.1.2
Evaluation of a power contactor ..........................................................................................52
9.4
Result when using a 3WL circuit breaker ............................................................................53
9.5
Result when using a power contactor .................................................................................53
10
10.1
10.2
10.3
10.3.1
Evaluation of "Respond" with two power switching devices .................................................58
10.3.1.1
Evaluation of two 3WL circuit breakers connected in series ................................................58
10.3.1.2
Evaluation of two power contactors connected in series......................................................59
10.3.2
Result of "Respond" with two 3WL circuit breakers .............................................................60
10.3.3
Result of "Respond" with two power contactors ..................................................................60
10.4
Result when using two 3WL circuit breakers .......................................................................60
10.5
Result when using two power contactors ............................................................................61
11
Evaluation of the safety function according to EN 62061 .................................................................. 63
11.1
11.2
11.3
11.3.1
Evaluation of "Respond" with two power switching devices .................................................66
11.3.1.1
Evaluation of two 3WL circuit breakers ...............................................................................66
11.3.1.2
Evaluation of two power contactors ....................................................................................67
11.3.2
Result "Respond" when using two 3WL circuit breakers ......................................................67
11.3.3
Result "Respond" when using two power contactors ...........................................................68
11.4
Result when using two 3WL circuit breakers .......................................................................68
11.5
Result when using two power contactors ............................................................................69
6
Application document for functional safety STO, SS1 (ISO 13849-1)
Compact User Manual, 09/2016, A5E34871844AM