Event Category - Error (0x1)
Event Component Type - Enclosure (0x0, 0xA)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_EDL_MEL_SWAPPED_B
RecoveryFailureType - REC_ESM_FACTORY_DEFAULTS_MISMATCH ( esmConfigSettingsMismatch.html )

MEL_EV_ESM_DRIVE_BYPASS - 0x2854

This event occurs when: A Fibre Channel drive port is bypassed by an ESM because the error thresholds
have been exceeded.
Event Name - ESM Drv Bypass
Event description: Drive port bypassed - Error thresholds exceeded
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_DRIVE_FAULT
RecoveryFailureType - REC_DRIVE_BYPASSED_SINGLE_PORT ( bypassedDrive.html )

MEL_EV_CONT_ID_READ_FAILURE - 0x2855

This event occurs when: An alternate controller board ID cannot be read.
Event Name - Alternate Board Controller ID Cannot Be Read
Event description: Controller cannot read alternate controller board ID
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_ALT_CTLR_BOARD_ID_UNREADABLE ( ctrlNoIdentifier.html )
.